User's Manual

Octopus ATM Defense System
Installation and Operation Guide
PageT3
3. Activate or select function for onboard sensors.
ON BOARD SENSOR Canadian U.S. Brazil
Light Sensor
Not placed Not placed Required
Function selected by jumper
on J2
Tilt Sensor
Required
Built in
Required
Built in
Required
Built in
Thermal Sensor
Required
Built in
Required
Built in
Required
Built in
Motion Sensor
Optional
Function selected by jumper
on J24. The default
condition is motion enabled.
Optional
Function selected by jumper
on J24. The default condition
is motion enabled
Optional
Function selected by jumper
on J24. The default condition
is motion enabled
Table 2. On-board sensor input selection table.
4. Pull the signal wires to a convenient place for testing the operation of the system. Depending on the
configuration of the switch the mechanical contacts to be used should be the common connection (usually
marked COM) and the N/O connection (usually marked NO or N/O).
In cases where the indicator switch must be closed (activated) when the door is open the normally closed contact
(usually marked NC or N/C).
5. To place the unit into TEST mode, hold down the Press-To-Test-Button while removing and reinstalling the
power jumper. Unit will beep 5 times quickly to signal the mode. If the light sensor is attached the unit will
see light and beep three times. This mode will last 10 minutes unless the user presses the POST button to
release the unit to normal mode.
6. In its shipped configuration, a buss-bar will be shorting the Manual Fire/Breach input and the Generic NC
input 2. If the unit has no connections or if all connections are in normal STANDBY mode configuration the
unit will blink its red LED 1 time per second. (
, , )
TEST MODE LASTS FOR 10 MINUTES. If during the test the red LED stops blinking, you must remove the
cover, and hold the Press-To-Test-Button while removing/re-installing the power jumper.
7. If any sensor is not in normal condition the LED will display a hex code of the highest priority sensor. With
the following exceptions:
a) Power Loss Detection is not enabled unless +2 to5 VDC is first applied between terminal
block position 3 and ground (position 2 or 6).
b) Generic NC input #1 is ignored unless the Generic NC input # 1 is enabled is enabled by
first shorting pin 7 to pin 4 on the sensor array cable.
Power detection and Generic NC input # 1 must be re-enabled each time the unit is placed in test mode.
If Power Detection is enabled and all inputs except the shorting bar are removed is displayed.
If Generic NC 1 is used is and all inputs except the shorting bar are removed
is displayed.
8. Using table 3 below resolve any improper configuration.
The system is wants to see the default STANDBY Mode conditions:
Door Open
Generic NC input 2 open
Manual Fire NC/Breach Closed (buss-bar)
Generic NC input 1 closed if sensor array inputs are used (see step 7).
+2 to 5 VDC on Power Loss input either terminal block or sensor array cable if power
detection is to be used (see step 7).