II. General CSU Test Mode Operation.
1. Place unit in Test mode by holding the POST button while powering the unit.
2. If unit is tilted beyond 50 degrees for 2 seconds it will beep 1 time.
3. If the squib jumper is not shorted or the Disable Squib jumper is not placed, the unit will beep 2 times.
4. If there is a transition of light (dark to light, or light to dark) the unit will beep 3 times (if light sensor is
installed and active).
5. If the unit senses thermal shock or senses temperature below 0 deg C or above 72 deg C the unit will beep 5
times.
Available Test Inputs:
Tilt
Thermal shock
Squib shorted or Disable squib jumper missing
Light sensor
6. If no sensors are active the unit will do nothing.
7. Pressing the POST button while in Test mode releases the unit from test mode.
Procedure:
Cassette staining units should be complete and MCU position testing complete per installation instructions.
1. Insure that all cassette staining units have their ink blocks disconnected. The ink block wiring must be
replaced with a shorting shunt that was provided when the unit shipped. Without the shorting bars the CSUs
will not pass self-test.
2. Activate or select function for onboard sensors.
ON BOARD SENSOR Canadian U.S. Brazil
Light Sensor
Optional
Function selected by jumper
on J8. The default condition
is light enabled. Armed unit
will not fire on light
detection.
Optional
Function selected by jumper
on J8. The default condition
is light enabled. Armed unit
will not fire on light
detection.
Optional
Function selected by jumper
on J8. The default condition
is light enabled. Armed unit
will fire on light detection.
Tilt Sensor
Required
Built in
Required
Built in
Required
Built in
Thermal Sensor
Required
Built in
Required
Built in
Required
Built in
Disable Squib
Required
Default is jumper J3
installed. And squib wires
connected to the ink block
or shorting bar.
Required
Default is jumper J3
installed. And squib wires
connected to the ink block
or shorting bar.
Required
Default is jumper J3
installed. And squib wires
connected to the ink block
or shorting bar.
Table 4. On-board sensor input selection table.
3. To place the unit into TEST mode, hold down the Press-To-Test-Button while removing and reinstalling the
power jumper. Unit will beep 5 times quickly to signal the mode. If the light sensor is attached the unit will
see light and beep three times. This mode will last 10 minutes unless the user presses the POST button to
release the unit to normal mode.