User's Manual

Octopus ATM Defense System
Installation and Operation Guide
PageT6
4. If all sensors are correctly configured (and the unit is in the correct orientation) the unit will do nothing.
TEST MODE LASTS FOR 10 MINUTES.
If during the test the red LED stops blinking, you must remove the cover, and hold the Press-To-Test-Button while
removing/re-installing the power jumper.
The system is wants to see the default STANDBY Mode conditions.
Light sensor enabled with light detected or disabled.
Squib wire shorted and Disable Squib jumper installed.
Unit in correct orientation (H/V)
Temperature between 0 to +70 ºC
5. Tilt the unit beyond 50 degrees and hear 1 beep to indicate tilt.
6. Remove shorting bar from Squib wire or Remove Disable Squib Jumper (J32) and hear 2 beeps to indicate
system disabled.
7. Cover or expose the light sensor (if enabled) and hear 3 beeps to indicate light transition.
8. Heat or freeze the unit and here 5 beeps to indicate thermal violation.
Unit may be released out of test mode by:
a) Removing/re-installing the power jumper while not pressing the POST button
b) Pressing the POST button.
c) Waiting for it to time out ~ 10 minutes.
9. When released from test mode, the unit will beep 10 times to notify operator of mode transition.
10. When the unit leaves test mode it will return to STANDBY mode.