Octopus Installation & User Manual APPENDIX F
F1
Internal Siren Module
Appendix F Optional Features
Bank Alarm Interface
The Bank Alarm Interface feature enables the MCU to notify the bank’s alarm system
that the ATM has been attacked. A set of normally closed (NC) contacts are provided for
this purpose. Connection is made via either J14 or J15 using a standard RJ-11 connector.
Internal Siren Module
The Internal Siren Module is a self-powered 128 dB audio siren. The siren will alert
onlookers and possible witnesses that the ATM has been attacked. Once activated, the
siren will require battery replacement. The siren uses a standard 9V alkaline battery.
Breach Sensor
The Breach Sensor is used to detect drill or torch attacks on the ATM safe walls. The
circuit is normally closed until the sensor is penetrated or broken. The sensor is wired to
J31 pin 1 and J10 pin 2. The normally closed circuit is made up of a Mesh Panel (for
wide areas), and flat Taperwire (for small spot protection).
Mesh Panel
The Mesh Panel is an adhesive panel whose purpose is to provide penetration protection
for ATM safe walls. The customer should provide details as to the most likely methods of
attack and desired protection areas.