Installation  Manual  |  VISIX  PTZ  Network  Camera                                      VISIX  PTZ  Network  Camera     VSX-‐PTZ-‐2MP-‐EXT20,VSX-‐PTZ-‐2MP-‐EXT,  VX-‐2M-‐OP-‐PTZ20X  and  VX-‐2M-‐OP-‐PTZ30X   Installation  Manual     10225  Westmoor  Drive,  Suite  300,  Westminster,  CO  80021  |  www.3xlogic.
Installation  Manual  |  VISIX  PTZ  Network  Camera                     Thank  you  for  purchasing  our  product.  If  there  are  any  questions,  or  requests,  please  do  not  hesitate  to  contact  the   dealer.     This  manual  applies  to  VSX-‐PTZ-‐2MP-‐EXT20,VSX-‐PTZ-‐2MP-‐EXT,  VX-‐2M-‐OP-‐PTZ20X  and  VX-‐2M-‐OP-‐PTZ30X  5-‐Inch  Speed   dome  PTZ  network  cameras.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Regulatory  Information   FCC  Information   FCC  compliance:  This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  digital  device,  pursuant  to   part  15  of  the  FCC  Rules.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Safety  Instruction   These  instructions  are  intended  to  ensure  that  the  user  can  use  the  product  correctly  to  avoid  danger  or  property  loss.     The  precaution  measure  is  divided  into  ‘Warnings’  and  ‘Cautions’:   Warnings:  Serious  injury  or  death  may  be  caused  if  any  of  these  warnings  are  neglected.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Cautions:     ! Make  sure  the  power  supply  voltage  is  correct  before  using  the  camera.   ! Do  not  drop  the  camera  or  subject  it  to  physical  shock.   ! Do  not  touch  sensor  modules  with  fingers.  If  cleaning  is  necessary,  use  a  clean  cloth  with  a  bit  of  ethanol  and  wipe   it  gently.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Table  of  Contents   1   INSTALLATION  .........................................................................................................................................................................  7   1.1   INSTALLATION  AND  CABLING  .....................................................................................................................................................................
Installation  Manual  |  VISIX  PTZ  Network  Camera   1 Installation   Please  make  sure  that  the  device  in  the  package  is  in  good  condition  and  all  the  assembly  parts  are  included.       NOTE:  Do  not  drag  the  speed  dome  with  its  waterproof  cables  as  shown  in  Figure  1-‐1,  otherwise  the  waterproofing  can   be  damaged  and  rendered  ineffective.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Back  Box   Lock   Screw   Lens  Cover   Sticker   Protective   Foam   Lower  Dome     Figure  1-‐2 Remove  the  Lower  Dome     4) Install  the  dome  mount.  Please  refer  to  the  related  sections  in  Section  2  and  Section  3  for  specific  installation   methods  with  different  mounts.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Steps:   1) Apply   thread   tape   to   the   thread   of   the   pendant   adapter   and   rotate   the   pendant   adapter   to   the   mount.   Secure   the  pendant  adapter  to  the  mount  with  a  set  screw  (supplied).
Installation  Manual  |  VISIX  PTZ  Network  Camera     Figure  1-‐5 Align  the  Direction  Label   ③     Figure  1-‐6 Mount  the  Dome         10225  Westmoor  Drive,  Suite  300,  Westminster,  CO  80021  |  www.3xlogic.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Connecting  the  Cables   Before  you  start:   Please  make  sure  the  power  of  the  dome  is  off  before  connecting  the  cables.   The  cable  interfaces  of  speed  dome  are  shown  in  the  following  figures.  Please  refer  to  the  following  figure  to  connect   the  cables.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Alarm  In/Out  Connections   ! The  network  speed  dome  can  be  connected  with  alarm  inputs  (0~5VDC).
Installation  Manual  |  VISIX  PTZ  Network  Camera   2 Mounting  Applications   Before  you  start:   ! For  cement  wall,  you  need  to  use  the  expansion  screw  to  fix  the  mount.  The  mounting  hole  of  the  expansion  pipe   on  the  wall  should  align  with  the  mounting  hole  on  the  mount.   ! 1.
Installation  Manual  |  VISIX  PTZ  Network  Camera   ! The  wall  must  be  thick  enough  to  install  the  expansion  screws.   ! Please  make  sure  that  the  wall  is  strong  enough  to  withstand  more  than  8  times  the  weight  of  the  dome  and  the   mount.
Installation  Manual  |  VISIX  PTZ  Network  Camera   4) Install  the  speed  dome  on  the  mount.  Please  refer  to  Section  1.2  Installation  and  Cabling  for  installation   details.   Note:  Follow  the  same  instructions  described  above  for  the  short-‐arm  wall  mounting.  For  outdoor  applications,  please   adopt  the  water-‐proof  measures.
Installation  Manual  |  VISIX  PTZ  Network  Camera   ! Mounting  Accessories     Figure  2-‐7 Hex  Screws  (M8×30),  Nuts,  Spring  Washers  and  Flat  Washers     Corner  Mounting   Before  you  start:   The  corner  mounting  is  dependent  on  the  indoor/outdoor  90°  solid  corner  construction.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Nuts  and  Washers     Figure  2-‐8 Pull  the  Power  Line     NOTE:  Make  sure  that  the  cables  have  enough  length.  For  outdoor  applications,  please  apply  the  sealant  around  the   center  hole  for  waterproof.   1) Attach  the  gasket  then  the  wall  mount  to  the  corner  adapter.
Installation  Manual  |  VISIX  PTZ  Network  Camera   3) Install  dome  to  the  mount.  Please  refer  to  Section  1.2  Installation  and  Cabling  for  installation  details.   NOTE:  Follow  the  same  instructions  described  above  for  the  short-‐arm  wall  mounting.  For  outdoor  applications,  please   adopt  the  water-‐proof  measures.
Installation  Manual  |  VISIX  PTZ  Network  Camera     Figure  2-‐12 Stainless  Steel  Hoops     ! Mounting  Accessories       Figure  2-‐13 Hex  Screws  (M8×30)  and  Spring  Washers   Pole  Mounting   Before  you  start:   The  pole  mounting  is  dependent  on  the  indoor/outdoor  solid  pole  construction.
Installation  Manual  |  VISIX  PTZ  Network  Camera     Figure  2-‐14 Assemble  the  Pole  Adapter   Install  the  pole  adapter.   1) Pull  the  cables  through  the  center  hole.   2) Secure  the  three  stainless  steel  hoops  to  the  pole,  and  tighten  the  screws  of  the  hoops  with  a  screwdriver.
Installation  Manual  |  VISIX  PTZ  Network  Camera     Figure  2-‐16 Install  the  Wall  Mount     3) Install  the  speed  dome  to  the  mount.  Please  refer  to  Section  1.2  Installation  and  Cabling  for  installation   details.   NOTE:    Follow  the  same  instructions  described  above  for  the  short-‐arm  wall  mounting.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Protective   Foam   Back  Box   Lower  Dome   Lens  Cover   Sticker   Figure  2-‐17 Remove  the  Protective  Accessory     4) Drill  a  hole  on  the  ceiling  according  to  the  drill  template  (supplied).   NOTE:  ±2mm  of  the  diameter  of  the  circle  is  tolerable.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Lock   Lock       Figure  2-‐19 Locks  and  Lock  Screws   2) Push  the  back  box  into  the  mounting  hole  in  the  ceiling   3) Tighten  the  lock  screws  with  the  screwdriver  and  the  locks  will  automatically  rotate  outwards  to  secure  the  in-‐ ceiling  mount  to  the  ceiling.
Installation  Manual  |  VISIX  PTZ  Network  Camera     Figure  2-‐21 Install  the  Trim  Ring   1.6 CEILING  MOUNTING  APPLICATIONS   Before  you  start:   The  ceiling  mounting  is  dependent  on  the  indoor/outdoor  solid  ceilings  construction.  The  following  are  the  mandatory   preconditions  for  ceiling  mounting:   ! The  thickness  of  the  ceiling  must  ranges  from  5mm  to  40mm.
Installation  Manual  |  VISIX  PTZ  Network  Camera     Figure  2-‐22 Remove  the  Screws     2) Remove  the  in-‐ceiling  mount.     Figure  2-‐23 Remove  the  Mount     3) Install  4  bolts  to  the  screw  holes  as  shown  in  Figure  2-‐24.     10225  Westmoor  Drive,  Suite  300,  Westminster,  CO  80021  |  www.3xlogic.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Figure  2-‐24 Install  the  bolts     Wiring  For  Ceiling  Mounting  Applications   The  cables  of  dome  can  be  routed  either  from  the  top  or  the  side  of  the  back  box,  as  shown  in  Figure  2-‐25.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Cable  Hole   Screw  Holes     Figure  2-‐26 Mark  the  Screw  Positions     6) Secure  the  mounting  base  to  the  ceiling  with  set  screws.   ! If  the  speed  dome  is  installed  on  a  wooden  wall,  use  the  self-‐tapping  screws  to  secure  the  mounting  base.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Push  forwards   Push  upwards   Line  up   Spring   Lock  clip               Figure  2-‐28 Attach  the  Back  Box  to  the  Mounting  Base   NOTES:   ! Please  remove  the  protective  film  on  the  lower  dome  after  the  installation  is  finished.   ! Do  not  touch  the  bubble  of  the  lower  dome  directly  by  hand.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Appendix   Appendix  1  Statics,  Interference  Lightning  and  Surge  Protection   This  product  adopts  TVS  plate  lightning  protection  technology  to  avoid  damage  caused  by  pulse  signal  that  is  below   3000W,  like  instantaneous  lighting  stroke,  surging,  etc.
Installation  Manual  |  VISIX  PTZ  Network  Camera   When  the  speed  dome  is  installed  in  environment  where  is  relatively  insulating  to  the  earth,  e.g.,  cement  pole  or   cement  wall,  then  only  the  control  center  requires  proper  grounded  locally.  Refer  to  the  following  figure.
Installation  Manual  |  VISIX  PTZ  Network  Camera   NOTES:   ! Because  the  signal  transmission  media  of  fiber  optical  speed  dome  and  network  speed  dome  are  isolated  from  the   control  center,  they  must  be  grounded  locally  to  protect  dome  against  damages.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Grounding  for  Metal  Pole  Installation:     When  the  speed  dome  is  installed  in  environment  where  is  conductive  to  the  earth,  e.g.,  metal  pole,  then  the   grounding  of  dome  can  be  achieved  by  the  properly  grounded  metal  pole,  meanwhile,  the  control  center  must  be   grounded  locally  as  well.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Appendix  2  Waterproof   NOTES:   ! The  long-‐arm  wall  mount  is  recommended  for  the  outdoor  application  of  speed  dome.   ! You  cannot  use  the  short-‐arm  wall  mount  or  pendant  mount  for  outdoor  application,  because  it  is  not  water-‐ proof.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Long-‐arm  Wall  Mount   The  long-‐arm  wall  mount  is  recommended  for  the  outdoor  application.  The  arm  of  wall  mount  is  designed  with  a   certain  inclination  angle  to  prevent  incoming  water,  as  shown  in  Figure  A-‐6.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Appendix  3  Bubble  Maintenance   The  bubble  is  a  transparent  plastic.  The  dust,  oil  and  finger  print,  etc.  will  cause  scratch  or  image  blur.  Please  refer  to   the  following  method  to  clean  the  bubble.   6) Handling  dust   Use  oil  free  soft  brush  or  blowing  dust  ball  to  clean  the  dust.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Appendix  4  RS485  Bus  Connection   ! General  Property  of  RS485  Bus   According  to  RS485  industry  bus  standard,  RS485  is  a  half-‐duplex  communication  bus  which  has  120Ω  characteristic   impendence,  the  maximum  load  ability  is  32  payloads  (including  controller  device  and  controlled  device).
Installation  Manual  |  VISIX  PTZ  Network  Camera   1# 6# 控 主 备 设 Controller   Device   32# 15#   Figure  A-‐9  Star  Shape  Connection     For  such  case,  the  best  way  is  adding  a  RS485  distributor.
Installation  Manual  |  VISIX  PTZ  Network  Camera   Appendix  5  24VAC  Wire  Gauge  &  Transmission  Distance   The  following  table  describes  the  recommended  max.  distance  adopted  for  the  certain  wire  gauge  when  the  loss  rate  of   24VAC  voltage  is  less  than  10%.  For  the  AC  driven  device,  the  maximum  voltage  loss  rate  is  10%  allowable.
Appendix  6  Table  of  Wire  Gauge  Standards     Bare  Wire   Gauge(mm)   American  Wire   Gauge  AWG   British  Wire   Gauge  SWG   0.750   0.800   0.900   1.000   1.250   1.500   2.000   2.500   3.000   21   20   19   18   16   15   12         21   20   19   18   17   14       Cross-‐sectional   Area  of  Bare   Wire(mm2)   0.4417   0.5027   0.6362   0.7854   1.2266   1.