Data Sheet

4D SYSTEMS µCAM-II
© 2014 4D SYSTEMS Page 13 of 22 www.4dsystems.com.au
µCAM
II Serial Camera Module
7.2. INITIAL, GET PICTURE, SNAPSHOT, SET PACKAGE SIZE, RESET Commands
When an INITIAL, GET PICTURE, SNAPSHOT, SET PACKAGE SIZE, or RESET command is sent to the camera, the
camera will simply reply with an ACK if successful. Please refer to Section 6.9 and 6.10 for ACK/NAK information.
7.2.1. Example: Sending commands
INITIAL,
GET PICTURE,
SNAPSHOT,
SET PACKAGE SIZE,
RESET
ACK