User Manual
Table Of Contents
- 1. Getting started
- 2. Introduction
- 3. Preparation
- 4. About the terminal
- 5. Mounting and installing the terminal
- 6. Connecting to the terminal
- 7. Managing the terminal
- 8. Configuring the terminal
- 9. Configuring the traffic interfaces
- 10. Cross Connections
- Embedded cross connect switch
- The Cross Connections application
- The Cross Connections system requirements
- Installing the Cross Connections application
- Opening the Cross Connections application
- The Cross Connections page
- Setting the terminal's address
- Management and user ethernet capacity
- Setting card types
- Getting cross connection configuration from the terminals
- Creating cross connections
- Sending cross connection configuration to the terminals
- Saving cross connection configurations
- Using existing cross connection configurations
- Printing the cross connection configuration
- Deleting cross connections
- Configuring the traffic cross connections
- Cross connection example
- Symmetrical Connection Wizard
- 11. Protected terminals
- 12. In-service commissioning
- What you will need
- Checking the antenna polarization
- Visually aligning antennas
- Accurately aligning the antennas
- Synchronizing the terminals
- Checking performance
- Checking the receive input level
- Checking the fade margin
- Checking long-term BER
- Bit Error Rate tests
- Additional tests
- Checking the link performance
- Viewing a summary of the link performance
- What you will need
- 13. Maintenance
- 14. Troubleshooting
- 15. Interface connections
- 16. Alarm types and sources
- 17. Country specific settings
- 18. Specifications
- Ethernet interface
- QJET Quad E1 / T1 interface
- Q4EM Quad 4 wire E&M interface
- DFXO Dual foreign exchange office interface
- DFXS Dual foreign exchange subscriber interface
- QV24 Quad V.24 asynchronous data interface
- HSS Single high speed synchronous data interface
- External alarm interfaces
- Auxiliary interfaces
- AC Power supply
- DC Power supply
- Power consumption
- MHSB protection
- Ethernet interface
- 19. Product end of life
- 20. Abbreviations
- 21. Acknowledgments and licensing
- 22. Commissioning Forms
- 23. Index
Mounting and installing the terminal | 29
5. Mounting and installing the terminal
This section covers installing the hardware associated with the terminal. Before you begin a terminal
installation, read this section thoroughly.
Warning:
You must comply with the safety precautions in this manual or on the product
itself. 4RF does not assume any liability for failure to comply with these
precautions.
Required tools
No special tools are needed to install the terminal other than those required to physically mount the
terminal into the rack.
Installing the terminal
The terminal is designed for 19-inch rack mounting and is supplied with rack mounting brackets. The
rack brackets can be front, mid, or rear mounted (as shown below) to suit individual installation
requirements. Once the rack brackets are attached, carefully lift the terminal into position in the rack,
and fasten with screws and washers.