User's Manual

Alarm Types and Sources | 229
Aprisa SR User Manual
Receiver Alarms
Event ID
Event Display
Text
Default
Severity
Configuration
Type
Function
7
RSSI Threshold
warning(4)
Threshold Type
Alarm to indicate that the receiver RSSI
reading taken on the last packet received
is outside defined limits.
8
RX Synthesizer
Not Locked
critical(1)
Not
Configurable
Alarm to indicate that the receiver
Synthesizer is not locked on the RF
received signal.
9
RX CRC Errors
warning(4)
Error Ratio
Type
Alarm to indicate that the data received
on the RF path contains errors at a higher
rate than the defined error rate threshold.
Radio Interface Path Alarms
Event ID
Event Display
Text
Default
Severity
Configuration
Type
Function
34
RF No Receive
Data
warning(4)
Sample
Duration Type
Alarm to indicate that there is no data
received on the RF path in the defined
duration period.
Customer Equipment Interface Path Alarms
Event ID
Event Display
Text
Default
Severity
Configuration
Type
Function
10
Port 1 Eth No
Receive Data
warning(4)
Sample
Duration Type
Alarm to indicate that Ethernet port 1 has
no received input signal in the defined
duration period.
11
Port 1 Eth Data
Receive Errors
warning(4)
Error Ratio
Type
Alarm to indicate that Ethernet port 1
received input signal contains errors at a
higher rate than the defined error rate
threshold.
12
Port 1 Eth Data
Transmit Errors
warning(4)
Error Ratio
Type
Alarm to indicate that Ethernet port 1
transmitted output signal contains errors
at a higher rate than the defined error
rate threshold.
35
Port 2 Eth No
Receive Data
warning(4)
Sample
Duration Type
Alarm to indicate that Ethernet port 2 has
no received input signal in the defined
duration period.
36
Port 2 Eth Data
Receive Errors
warning(4)
Error Ratio
Type
Alarm to indicate that Ethernet port 2
received input signal contains errors at a
higher rate than the defined error rate
threshold.
37
Port 2 Eth Data
Transmit Errors
warning(4)
Error Ratio
Type
Alarm to indicate that Ethernet port 2
transmitted output signal contains errors
at a higher rate than the defined error
rate threshold.
13
Serial Data No
Receive Data
warning(4)
Sample
Duration Type
Alarm to indicate that the RS-232 port has
no received input signal in the defined
duration period.
14
Serial Data
Receive Errors
warning(4)
Error Ratio
Type
Alarm to indicate that the RS-232 port
received input signal contains errors at a
higher rate than the defined error rate
threshold.