User's Manual

Product Options | 37
Aprisa SR User Manual
Spares
The Aprisa SR Protection Switch is available as a spare part. This spare includes the protection switch and
two sets of Protection Switch interconnect cables (one set is 6 cables).
Part Number
Part Description
APSP-SRPSW
4RF Spare, Aprisa SR, Protection Switch
The set of interconnect cables is available as a spare part (set of 6 cables).
Part Number
Part Description
APSP-SRPSC-ST6
4RF Spare, Aprisa SR, Protection Switch Cables, Set Of 6
Replacing a Faulty Protection Switch
Note: Replacing a faulty Protection Switch will disrupt traffic.
Move the radios, the interconnect cables, the interface cables and the power cables to the replacement
Protection Switch.
On both Protected Station radios:
1. Power on the radio and wait for it to become ready.
2. Using SuperVisor > Maintenance > Advanced, enter the RF Interface MAC address shown on the
Protection Switch label (see RF Interface MAC address on page 142).
3. Using SuperVisor > Maintenance > Advanced, Decommission the node (see Decommission Node on
page 142) and then Discover the Nodes (see ‘Discover Nodes’ on page 142).
Ensure that the Hardware Manual Lock switch is set to the Auto position.
The Aprisa SR Protected Station is now ready to operate.