Instruction Manual

SCE-02 USB Interface Instruction Manual
1. Features
Connects a scale to a personal computer and used to transmit the scale weight data to the
personal computer via USB. Applicable OS is Windows 98SE or later.
As a standard Windows driver is used, complicated installation of a dedicated driver is not
necessary. Once a connection between the scale and the personal computer is made, the weight
data can be transmitted.
Transmits the scale weight data to any application such as Excel, Word or memo pad for Windows.
Notes: Only the weight data can be transmitted. Headers and units can not be transmitted.
Data transmission from the personal computer to the scale is not available. If it is
necessary to control the scale by a command, connect the scale and the personal
computer using the SCE-03 RS-232C serial interface.
SCE-02 and SCE-03 can not be installed at the same time
.
Turn off the screen saver or suspend mode of the personal computer.
Windows, Word and Excel are the registered trademarks of the Microsoft Corporation.
2. Installation Procedure
Note: Before installing the SCE-02 board, be sure to remove
the batteries from the scale.
Step 1 Hold the board in such a way that its USB mini port will
match the hole on the casing. Insert the board into the
casing by sliding it into the casing groove.
Step 2 Place the waterproof packing on the casing, aligning its
holes with the casing screw holes.
Step 3 Remove the four screws on the option slot panel located
on the bottom of the display.
Step 4 Insert the board into the option slot.
Step 5 Secure the casing to the display, using the four screws provided
with the casing.
Step 6 Seal the screw heads with the tabs attached to the
waterproof packing.
Step 7 Insert the USB mini-B cable (sold separately), into the port
at the rear of the casing.
3. How to use
Step 1 Turn the personal computer on to start up Windows. And then, insert
the batteries into the scale and turn the scale power on.
Step 2 Connect the scale to the personal computer, using the USB cable
.
Note: When connecting the USB cable, be sure that the scale data output mode is
set to a mode other than stream mode.
Step 3 For the first installation, the driver will be installed. For details, refer to “4.
Installation of the Standard Windows Driver”. For the second installation or
after, this step is not required.
Step 4 Start up the application (such as Excel) into which the scale weight data is transmitted.
Place the cursor in the position to enter the scale weight data.
Step 5 Press the scale PRINT key. The weight data is input at the cursor position.
Step 6 To finish the operation, disconnect the USB cable.
4. Installation of the Standard Windows Driver
Windows 2000 / Me / XP
Once connected, an automatic driver installation will start. Wait for the installation to complete.
Windows 98
Step 1 The “Add New Hardware Wizard” window
appears.
Click on “Next”.
Step 2 Check “Search for the best driver for your
device (Recommended).” and click on
“Next”.
Step 3 Uncheck all the items and click on “Next”.
Step 4 Make sure that “USB Human Interface
Device” is displayed and click on “Next”.
Step 5 Driver installation has started. When
completed, the window shown to the right
appears.
Click on “Finish”
Note: During installation, a message requesting to
insert the Windows 98 CD-ROM may appear.
In this case, insert the Windows 98 CD-ROM
and click on “OK”.
Waterproof
packing
Seal the screw heads
USB mini
port
Casing
Screws on
the option slo
t
USB mini-B
cable
3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN
Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148

Summary of content (1 pages)