SF/SG Series Price Computing Scales Instruction Manual WEIGHT 88888 kg Net Zero PRICE 8888888 Total $ M+ UNIT PRICE 888888 Change SF-15KA Max. 15kg Min 0.1kg e=0.
SF/SG Series Instruction Manual Index Item Number Description Page Unpacking and Inspecting 2 Specifications 3 Main Operating Components 4 1 Zero Point Adjustment 5 2 Tare Adjustment 5 3 Keypad Tare Entry 6 4 Setting a Unit Price 7 5 Storing a Unit Price in Memory 8 6 Recalling a Unit Price from Memory 8 7 Totaling Multiple Items with Unit Prices Stored in PLU Memory 8 8 Clearing Totaling Memory 9 9 Multiplier Function 9 10 Calculating the Correct Change 10 11 Clear E
Thank You... Thank you for purchasing our A&D SF/SG Series price computing scale. Before using your price computing scale, please read the operating instructions. Warning before connecting power plug: – – Do not place a load on the weighing pan before connecting the power supply. Check the power requirement label next to the power switch on the lower left side of the body of the SF/SG scale to confirm that it corresponds to your local power requirements. Or when appropriate, check the AC adapter.
SF/SG Series Specifications Specification Table Price Lookup Capability Options AC hardwired None AC hardwired None AC hardwired None 30 30 30 RS-232C RS-232C RS-232C Tower Tower Tower AC adapter AC adapter AC adapter 6 D size 6 D size 6 D size 30 30 30 RS-232C RS-232C RS-232C VFD VFD VFD Tower Tower Tower AC adapter AC adapter AC adapter Rechargeable* Rechargeable* Rechargeable* 30 30 30 RS-232C RS-232C RS-232C LCD LCD LCD Table top AC adapter Table top AC adapter Table top AC adapter 6 D
SF/SG Series Main Operating Components WEIGH NET ZER T WEIGHT kg UNIT PR 88888 O 9 5 10 6 2 7 3 8 4 7 8 9 4 5 6 1 2 3 C 88888 PRICE 888888 $ 8888888 11 12 CHA NGE 0 ( 1 ICE $/k g ( Power Switch turns the power to the unit on and off.
SF/SG Series Operating Instructions 1. Zero Point Adjustment The zero point is automatically adjusted when power is turned on. If the display shows a positive or negative weight, the scale must be re-zeroed. How to re-zero: Step 1: Assure that nothing is on the weighing pan. 0 Step 2: Press . ZERO Step 3: The WEIGHT display should read: NET ZERO SG series SF series 0.000 0.000 NET ZERO 2.
SF/SG Series Operating Instructions 3. Keypad Tare Entry Note: Usually this function is inhibited. If necessary, please ask your dealer. In addition to the tare adjustment described on the previous page, another tare adjustment is available. It is to enter a TARE value with the numerical keypad. How to enter a TARE using the numerical keypad: Step 1: With nothing on the weighing pan, turn on the SF/SG scale. The display should read: UNIT PRICE WEIGHT 0.00 0.
SF/SG Series Operating Instructions Note about keypad tare entry: • When a TARE weight has been set, an error message “ enter a lower value than the TARE weight. Err tr ” will appear as shown below, if you • If you enter a TARE weight greater than the weighing capacity of the scale, an error message “ will appear as shown below. Err tr ” WEIGHT UNIT PRICE PRICE 0.000 ------ Err tr NET ZERO ( ( • To release the error shown above, press to return to the weighing mode.
SF/SG Series Operating Instructions 5. Storing a Unit Price in Memory Unit prices can be stored in memory for quick recall, by assigning a unit price to a Price Lookup (PLU) key. The SF series scale has 30 PLU keys, thus can store 30 unit prices. The SG series scale has 12 PLU keys, thus can store 12 unit prices. Assign a unit price to a PLU key as follows: Step 2: Press Step 1: Enter a unit price using the numerical keypad. kg UNIT P RICE $/kg 0.
SF/SG Series Operating Instructions Final Step - Recalling the TOTAL ( ( Press . Each display reads: WEIGHT MODE UNIT PRICE Total PRICE 2 550.00 Total Number of items calculated Totaling Indication (TOTAL mode) Total Price 8. Clearing Totaling Memory Step 1: While in the TOTAL mode, press C . Note about Totaling Items: • The numerical keypad, PLU keys, and transaction. X MULTIPLIER key may all be used during a single (See “9. Multiplier Function” below.
SF/SG Series Operating Instructions 10. Calculating the Correct Change The purpose of this function is to allow the operator to determine the correct change to return to the customer once payment has been made. Example: There have been 4 entries and the total cost of the transaction is $80.00. ( ( Step 1: Press MODE WEIGHT UNIT PRICE 4 total . The scale displays: PRICE 80.
SF/SG Series Operating Instructions 12. Automatic Cancellation of a Unit Price In very busy applications, it may be more convenient for the Unit Price entry to return to zero after each operation. Note: To use this function, F2 must be set to 0. Refer to “13. Setting “F” Functions”. To do this, press while the display is in normal operation. 1 CHANGE WEIGHT UNIT PRICE ut PRICE Automatically clears the unit price.
SF/SG Series Operating Instructions Settings F1: Auto display off F2: Cancellation of unit price F3: Output Data (Refer to the note below.
SF/SG Series Operating Instructions 14. Connecting the Scale to the AD-8124 Label Printer Note about Connection to the AD-8124 • To connect the SF/SG scale to the printer, use an RS-232C crossover cable (D-Sub 9-pin socket type) such as an AX-KO1371-200 (2 m). • To get optimum performance from the AD-8124, use the SF/SG program version “rP 4.00 ” or later.
SF/SG Series Operating Instructions 14-3 Setting the printer internal clock Set the printer internal clock as follows: Example: Set the clock to 9:45, June 10, 2001. Step 1: While holding down T , turn the scale’s power switch on. All the displays TARE indicate “- - - - - - -” as shown below: WEIGHT UNIT PRICE PRICE ------ ------ ------ Assure that the printer power switch is turned on. Step 2: Enter the date and time using the numerical keypad.
SF/SG Series Operating Instructions Step 6: Press the PLU 2 key. The data will be sent to the printer and the scale will return to the normal weighing mode. If the scale will not return to the normal weighing mode, check the values entered. Step 7: Using the numerical keypad, enter “1”, “0”, “0”, “6”, “2”, “0”, “0”, “1”, “0”, “9”, “4” and “5” in this order. If an error is made, press C to clear the values. And re-enter the values.
SF/SG Series Operating Instructions Step 2: Using the numerical keypad, enter a 3-digit label number. If an error is made, press C to clear the values. And re-enter the values. SF series SG series WEIGHT set ln PRICE 012 WEIGHT UNIT PRICE set ln PRICE 012 UNIT PRICE Step 3: Press the PLU key to assign to the label number, in this example, the PLU 5 key. . The PLU number will be sent to the printer and the scale will return to the displays described in step 1.