SJ-1000H SJ-2000H SJ-5000H SJ-12KH WM+PD4001280A
SAFETY PRECAUTIONS All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows: WARNING CAUTION A potentially hazardous situation which, if not avoided, could result in death or serious injury. A potentially hazardous situation which, if not avoided, may result in minor or moderate injury. This manual is subject to change without notice at any time to improve the product.
PARTS DESCRIPTION Weighing Platform ON/OFF key Spirit level Turns the scale power on/off. UNITS key Changes weighing units, (k)g, lb, oz or lb-oz. RE-ZERO key Display Sets display to zero or subtracts weight of container. Battery cover AC adapter jack Four leveling feet Battery indicator STABLE indicator Indicates when the reading is stable. Indicates battery remaining amount. It turns on about for 10 seconds when powered on.
PREPARATION Installing Batteries CAUTION Take great care of the polarity of batteries. The polarity marks are shown in the battery box. Replace used batteries with four new ones when lb is displayed. Do not mix used and new batteries. Do not mix the battery type. Remove batteries when the scale is not to be used for a long time. Battery box 2 1 3 New four batteries (R20P / LR20 / D size) Battery cover 1 Slide the battery cover downward to open. 2 Push the battery box to unhook and pull it out.
Before Weighing WEIGHING Automatic power-off function. If the scale left ON and the stable indicator is displayed, an automatic power-off function turns power off after approximately 5 minutes. To disable/enable this function, turn the scale on while pressing the [RE-ZERO] key. Then poff0 or poff1 will be displayed. poff0 Function disabled. poff1 Function enabled. Select the setting by pressing the [RE-ZERO] key which toggles the display above, and press the [UNITS] key.
CALIBRATION When to Calibrate Calibration may be required when it initially installed or it is moved a substantial distance. Also periodical calibration will be recommended. Calibration using a Calibration Weight Calibration switch 1. Enter calibration mode. Press the [ON/OFF] key to turn the power off. While pressing both the [RE-ZERO] and [UNITS] keys, press the [ON/OFF] key. Cal will be displayed.
SPECIFICATIONS MODEL (k)g Capacity lb x Resolution oz lb-oz Non-linearity Repeatability Span drift Operating temp. Display Display update Power Battery life Platform size SJ-1000H SJ-2000H SJ-5000H SJ-12KH 1000 g x 0.5 g 2000 g x 1 g 5000 g x 2 g 12 kg x 5g 2.2 lb x 0.001 lb 4.4 lb x 0.002 lb 11 lb x 0.005 lb 26 lb x 0.01 lb 35 oz x 0.02 oz 70 oz x 0.05 oz 176 oz x 0.1 oz 423 oz x 0.2 oz 2.2 lb x 0.1 oz 4.4 lb x 0.1 oz 11 lb x 0.1 oz 26 lb x 1 oz ±1 g ±2 g ±5 g ±10 g 1g 2g 5g 10 g ±0.
3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148 http://www.aandd.co.jp/ A&D ENGINEERING, INC. 1555, McCandless Drive, Milpitas, CA. 95035 U.S.A. Telephone: [1] (408) 263-5333 Fax: [1] (408)263-0119 A&D INSTRUMENTS LTD.