Digital Scale HL-WP Series HL-1000WP HL-300WP HL-3000WP WM+PD4000754
SAFETY PRECAUTIONS All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows: WARNING CAUTION A potentially hazardous situation which, if not avoided, could result in death or serious injury. A potentially hazardous situation which, if not avoided, may result in minor or moderate injury. This manual is subject to change without notice at any time to improve the product.
PARTS DESCRIPTION Weighing Platform Display ON/OFF key Turns the scale power on/off. RE-ZERO key Sets display to zero or subtracts weight of container. Spirit level UNITS key (g/lb and g/lb-oz models only) Changes weighing units, g or lb (oz). Four leveling feet g/lb model: HL-1000WP g/lb-oz model: HL-300WP/HL-3000WP Rubber cap Battery cover AC adapter jack (Batteries are not included.) Battery compartment STABLE indicator Indicates when the reading is stable.
PREPARATION Installing the Batteries / Connecting The AC adapter Installing the Batteries CAUTION When replacing batteries, be careful not to apply too much force to the weighing pan. An excessive force could damage the scale. Stop up with the rubber cap Remove the battery cover and insert six batteries (R6P / LR6 / AA size) into the battery compartment, taking extreme care to that the polarities plus and minus are observed.
WEIGHING Before weighing Be aware of the Automatic power-off function. If this unit is left ON and the stable indicator is displayed, an automatic power-off function turns power off after approximately 5 minutes. To disable this function, press the [ON/OFF] key while pressing the [RE-ZERO] key. p- XX will be displayed and the scale returns to the weighing mode.
CALIBRATION When to calibrate Calibration may be required when the scale initially installed, if it is moved a substantial distance, or in accordance with local regulations. This is necessary because the weight of a mass in one location is not necessarily the same in another location. Also, with time and use, mechanical deviations can occur. The position of the [UNITS] key for the Calibration The g model has no [UNITS] key, but the key used to enter calibration is located under the overlay.
Calibration by gravity compensation If you have calibration weights at the capacity of the scale, you can calibrate the scale with the weights instead of compensating for acceleration due to gravity. 2 The scale is calibrated at 9.798 m/sec at the factory. If the gravity acceleration at your location is not same, calibrate the scale by compensating for the gravity acceleration. (Refer “The Value of Gravity at Various Locations” and “World Map” and find your location value.) 1. Enter calibration mode.
SPECIFICATIONS MODEL Capacity Resolution Non-linearity Repeatability Span drift Operating temp. Display Display update Power Battery life Platform size Dimensions Weight (approximately) Calibration weight Accessories Options HL-1000WP HL-300WP HL-3000WP 1000 g 300 g 3000 g 2.2 lb 10.58 oz 6 lb 9.8 oz 0.5 g 0.1 g 1g 0.001 lb 0.01 oz 0.1 oz ±1 g ±0.2 g ±2 g 0.5 g 0.1 g 1g ±0.015% / °C TYP (5°C~35°C / 41°F~95°F) -10°C~40°C / 14°F~104°F, Less than 85%RH 12 mm / 0.
World Map 8
3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148 A&D ENGINEERING, INC. 1555 McCandless Drive, Milpitas, CA. 95035 U.S.A. Telephone: [1] (408) 263-5333 Fax: [1] (408) 263-0119 A&D INSTRUMENTS LTD. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxon, OX14 1DY United Kingdom.