Instruction Manual

HV-G/HW-G Series Page 35
10. Accumulation Function
10.2. Operation and Performance (Examples)
Example 1
In this example, the scale accumulates the value each time an article is weighed. The
function parameter is set to f8 3 .
Step 1 Press the MODE key to display or .
Step 2 Press the ZERO key to reset the accumulation data.
Step 3 Return to the kg mode using the MODE key.
Step 4 Place an article on the pan. Wait for the stability mark to be displayed and the value
to be blinking. Remove the article and press the ZERO key.
Step 5 Weigh additional articles using step 4.
Step 6 Press the MODE key to display the accumulation count and accumulated mass
value with
or .
Example 2
In this example, the scale accumulates the articles that are removed from the pan.
The function parameter is set to f8 4 .
Step 1 Enter the kg mode using the MODE key.
Place all articles on the pan and press the TARE key.
Step 2 Press the MODE key to display or .
Step 3 Press the ZERO key to reset the accumulation data.
Return to the kg mode using the MODE key.
Step 4 Remove an article from the pan. Wait for the stability mark to be displayed and the
value to be blinking. Press the TARE key.
Step 5 Weigh additional articles using step 4.
Step 6 Press the MODE key to display the accumulation count and accumulated mass
value with or .