Instruction Manual

HV-G/HW-G Series Page 53
15. The Function Table
Item Display Description
f6 4
When the weight value becomes stable after the SET key is
pressed, the scale compares the weight value. It does not compare
on an unstable condition. Press the SET key again to stop the
comparison.
A
A
A
A
f6 5
When the weight value is stable, the scale compares the weight
value. It does not compare on an unstable condition.
A
A
f6 6
When the weight value becomes stable and not nearly-zero after
the SET key is pressed, the scale compares the weight value. It
does not compare on an unstable condition.
Press the SET key again to stop the comparison.
A
A
A
f6 7
When the weight value becomes stable and not nearly-zero, the scale
compares the value. It does not compare on an unstable condition.
A
A
f6 8
Simple batch function. (Refer to “13. Simple Batch Function”)
Comparator
f6 9
Full/dribble batch function. (Refer to “12. Full/Dribble Batch Function”)
Selects the condition of the buzzer on option OP-03 by
comparator function or full/dribble batch function.
f7 0 # No buzzer.
f7 1
The buzzer sounds at LO.
f7 2
The buzzer sounds at OK.
f7 3
The buzzer sounds at LO and OK.
f7 4
The buzzer sounds at HI.
f7 5
The buzzer sounds at LO and HI.
f7 6
The buzzer sounds at OK and HI.
f7 7
The buzzer sounds at LO, OK and HI.
Buzzer
f7 8
The buzzer sounds at the end of the full/dribble batch process.
Select the condition of the accumulation function
f8 0 # Accumulation function not used.
A
f8 1
The scale accumulates the data, if the F key is pressed, when
the display is a positive stable value and not nearly-zero. The
next accumulation can be performed after the display becomes
nearly-zero or a negative value.
A
A
A
A
f8 2
The scale accumulates the data, if the F key is pressed, when
the display is a stable value and not nearly-zero. The next
accumulation can be performed after the display becomes
nearly-zero.
A
A
A
Accumulation
function
f8 3
When the display is a positive stable value and not nearly-zero,
the scale accumulates the data automatically. The next
accumulation can be performed after the display becomes
nearly-zero or a negative value.
Use: After weighing the first unit sample, one after another, it
records the total count and total weight value.
A
A
A
"#": factory settings. The "nearly-zero" is within ±5 digits from zero point in the unit of kg.