Quick Start Manual For use with software versions 1.5+ 6500-601 Rev 1.
Introduction The 6500 is a member of the latest generation of Ranger remote displays.
Installation Wall Mounting Using the four mounting clips shipped with the unit, follow the instructions below: 1. 2. 3. 4. 5. 6.
Power Connection The 6500 operates from an AC power source between 110 VAC and 240 VAC. The power connection must be performed under the requirements and regulations of your state laws. ! Warning: The 6500 contains hazardous voltages. Disconnect power before opening. 1. Remove 2 Screws 2. Slide Power Supply Out 3. Connect AC Supply 4. Slide Power Supply In 5.
Remote Display Serial Wiring Diagrams RS232 Ranger 6500 Primary RS232 TXD RXD GND Ranger 5000/5100 or PC 2 3 5 RS422/RS485 Ranger 6500 Primary RS422 Ranger 5000/5100 RX- 6 RX+ 7 TX- 8 TX+ 9 RXRX+ TXTX+ 20mA Current Loop Connections to a Passive Loop Transmitter + - EX+ L+ SH LEX- 6500 Loop Connector Page 4 Ranger Loop Transmitter (RI 0214)
Ranger and Supported Indicators ITEM EDIT Default setting: [ ] Press and hold the Group key ( GROUP ) until "Remote Setup 6500" appears. GROUP BRAnD Configure remote display operate from indicator type.
Notes on Ranger Indicators * Ranger Auto Output Strings RngerA STX Sign Weight(7) Status ETX RngerC STX Sign Weight(7) S1 S2 S3 S4 Units(3) ETX RngerD STX Sign Weight(7) ETX RngerE STX Sign Weight(7) S5 Units(3) Mode(4) ETX Operation with Ranger Indicators The 6500 is designed to operate with Ranger Auto Output Format A (Rnger A), regardless of other user configured indicators.
Non-Supported Indicators ITEM Default setting: [ ] [SCAn], RS232, RS422, Loop EDIT Press and hold the Group key ( GROUP ) until "Remote Setup 6500" appears. GROUP SERIAL SRC Data source BAUD Baud rate BITS Serial format configuration 1stop 2stop -none Term [AUTO], 300, 600, 1200, 2400, 4800, 9600, 19200 [n81-] n 8 1 Parity Databits Stopbits Network 8bits 7bits [YES], NO [5], 10, 20, noTMO (no time out) [00] - 99 Odd Even ITEM to change position, EDIT none to change digit.
ITEM BLK 1-BLK 4 Configurable data blocks SAVING SAVED Reset blocks to defaults RESET [R, 1, 2, 3, 4] EDIT [ConT n] / ConT Y Default setting: [ ] Enable/disable data blocks ITEM to change position, EDIT to enable/disable PRESET Select format to preset: [1], 2,3,4 Preset brand to different blocks Select indicator (Refer to Ranger and Supported) EnABLE Refer to token list Non-Supported Indicators (continued) GROUP BLOCK -EndExit setup NoSAVE (If data not changed) Page 8 To Enter Hold GROUP
6500 Configuration Using Viewer Configuration of the 6500 can be performed using the Ranger 6500 Viewer software for Microsoft Windows. The 6500 must be connected to the PC using the secondary RS232 port located behind the units plate. Wiring requirements for the cable are given below. The secondary serial port must be configured as a Network Slave, however this is the default operation of this port.
Other Operating Modes The configuration of these modes is beyond the scope of this manual. Please refer to the Reference Manual for a full description. These modes are available from the Serial Setup menu, accessed by holding the ITEM key, and selecting the required mode. Summing Network Master The 6500 queries and sums the weight of a number of slave 5000 / 5100 units connected together on a multidrop RS422/RS485 bus. The resulting total weight is displayed on the 6500.
(This page left intentionally blank) Page 11
(This page left intentionally blank) Page 12
(This page left intentionally blank) Page 13
Error Messages Configuration Errors Error Description ER.DAT There is no data being received by the unit. ER.RX The baud rate/parity or stop bits are incorrect. ER.ETX No ETX character was found in the data stream. ER.FLD The data stream does not match any format. ER.LEN The field to be displayed is longer than 6 digits. Weighing Errors (U-----) The weight is below the minimum allowable weight reading. (O-----) The weight is above the maximum allowable weight reading.
N2708 This document contains a general guide only of the operation of the product and shall not form any contract. The specifications of the product may be altered without notice. RANGER INSTRUMENTS www.rangerinstruments.com sales@rangerinstruments.