The Standard format results in data after the output from an A&O
industrial scale or electronic balance is internally processed and
formatted. Printing timing, cumulative total, etc. are taken, (For the input
data of the standard format, refer to "Applications," p. 21.)
Printing form
Switch #4
Select the printing direction.
Normal character Printing direction
12/31/99 11:59 PM
600.0kg
inverted character Printing direction
When Normal characters are selected they seem to be inverted during
printing, but the printing process is the same as the input data process.
Inverted characters selected seem to be normal, but the printing process is
the opposite of the input data process.
Status printing Switch #5
Changes over to enable/disable the data at minus/unstable.
Printing character Switch #6
Choose either standard character size (5x7 dots) or
enlarged (10 x 7).
Key input
Switch #7
Enable or disable the key inputs from the front panel.
Setting mode change Switch #8
if this DIP switch is selected the unit is in the setting mode explained below.
Function Setting Mode
Setting mode can only be accessed when DIP switch #8 is turned ON.
Then, while pressing the SET UP key, press the M+.PRT.key at the same
time. The following message is printed:
FUNCTION 1 1
You are now in the Function mode, press the TOTAL key to change the
Function No, and same format used for printing. Press the M+.PRT. key to
increase the function level, press the CLEAR key to decrease the function
level.