Product specifications

AD-4402 Page 117
Category address
:
[Function] - [Function setting] - [Sequence] - [Control]
Category
address
symbol
Name Descriptions
Range
and
choices
Default
5q f-14
Batch finish actions
Select an action at batch finish.
Bit 1: Auto-start mixing
(Start mixing automatically)
Bit 2: Auto-start discharge
(Start discharge automatically)
0: No (Not used)
1: Yes (Use)
00
to
11
00
5q f-15
Discharge finish
actions
Select an action at discharge finish.
Bit 1: Auto-clear tare
(Clear tare automatically)
Bit 2: Start mixing
(Start mixing automatically)
0: No (Not used)
1: Yes (Use)
00
to
11
00
5q f-16
Recipe start actions
Selection of re-zeroing at recipe start.
0: No (Not used)
1: Yes (Use)
0 to 1 1
5q f-17
Recipe finish
actions
Select an action at recipe finish.
Bit 1: Auto-clear tare
(Clear tare automatically)
Bit 2: Auto-start mixing
(Start mixing automatically)
Bit 3: Auto-start discharge.
(Start discharge automatically)
0: No (Not used)
1: Yes (Use)
000
to
111
000
5q f-18
Maximum number
of compensation
Set the number of compensation flow.
When 0 is set, there is no flow.
0 to
255
0
5q f-19
Comparison flow
Eval
Set the condition with compensation
close timer and stability.
0: Timer is up
Comparison when compensation
close timer is up.
1: Stable and timer is up.
Comparison after stable mark and
compensation close timer is up.
2: Stable or timer is up.
Comparison after stable mark or
compensation close timer is up.
0 to 2 0
5q f-20
Free fall
compensation
0: No (Not used)
1: Average of last four free fall times.
2: Real time free fall compensation
0 to 2 0