SF/SG Series Instruction Manual Index Item Number Description Page Unpacking and Inspecting 2 Specifications 3 Main Operating Components 4 1 Zero Point Adjustment 5 2 Tare Adjustment 5 3 Keypad Tare Entry 6 4 Setting Unit Price 7 5 Storing a Unit Price in Memory 8 6 Recalling a Unit Price from Memory 8 7 Totaling Multiple Items with Unit Prices Stored in PLU Memory 8 8 Clearing Totaling Memory 8 9 Multiplier Function 9 10 Calculating Correct Change for the Customer 10
Thank You... Thank you for purchasing our A&D SF/SG Series price computing scale. Before using your new price computing scale, please read the operating instructions. Warning before connecting power plug: – – Do not place a load on the weighing pan before connecting the power supply. Check the power requirement label next to the power switch on the lower left side of the body of the SF/SG to confirm that it corresponds to your local power requirements. Or when appropriate, check the AC adapter.
SF/SG Series Specifications Specification Table Model Capacity Display Type SF- 6KA SF-15KA SF-30KA 6kg x 2g 15kg x 5g 30kg x 10g VFD VFD VFD SF- 6KB SF-15KB SF-30KB 6kg x 2g 15kg x 5g 30kg x 10g SF- 6KC SF-15KC SF-30KC SG- 6KA SG-15KA SG-30KA Price Lookup Capability AC Type Battery Type Options Tower Tower Tower AC hardwired AC hardwired AC hardwired No No No 30 30 30 RS-232C RS-232C RS-232C LCD LCD LCD Tower Tower Tower AC adapter AC adapter AC adapter 6 D size 6 D size 6 D size 30 3
SF/SG Series Main Operating Components Power Switch turns the power to WEIGH T WEIGHT kg UNIT PR ICE $/k g 88888 NET ZE RO 9 5 10 6 2 7 3 8 4 888888 88888 $ 88 8 8 8 8 8 CHANGE 7 8 9 1 0 4 5 6 1 2 3 C ( 1 11 12 PRICE ( the unit on and off.
SF/SG Series Operating Instructions 1. Zero Point Adjustment The zero point is automatically adjusted when power is turned on. If the display shows a positive or negative weight, the scale must be re-zeroed. How to re-zero: 1. Assure that nothing is on the weigh pan. 2. Press 0 ZERO 3. “ 0 ” should appear on the weight display NET ZERO Table top type Tower type 0.000 0.000 NET ZERO 2.
SF/SG Series Operating Instructions 3. Keypad Tare Entry (Usually this function is inhibited. If necessary, please ask your dealer.) In addition to pressing T TARE to TARE out an empty container that has been placed on the weigh pan, it is also possible to enter a TARE value with the numerical 10 key pad. How to enter TARE using the 10 Key Pad: Step 1: With no weight on weigh pan, turn on the SF/SG. Display’s will read: UNIT PRICE WEIGHT 0.000 0.
SF/SG Series Operating Instructions Note about keyboard TARE: 1. If you enter a tare weight greater than the weighing capacity of the scale an error message will display: “ Err tr ” 2. When a TARE weight has been set, it is not possible to set a new TARE weight of a lower value by the instructions above. It is necessary to delete the previous TARE first, before entering a TARE of lower value. Example WEIGHT UNIT PRICE PRICE 0.000 ------ Err tr NET ZERO 3.
SF/SG Series Operating Instructions 5. Storing a Unit Price in Memory It is possible to store unit prices in memory for quick recall. A. The SF model has 30 Price Look-Up keys (PLU). B. The SG model has 12 PLU’s The following instructions explain how to assign a unit price to a PLU key. Step 1: Enter desired unit price by the 10 key pad. Step 2: Press MEM 0.000 NET ZERO 9 O 5 1 10 6 2 11 7 3 12 UNIT P RICE $/kg 5.50 CHANGE 7 8 4 4 1 8 5 2 9 10 6 3 PRICE ..
SF/SG Series Operating Instructions Note about Totaling Items: A. X The 10 key pad, PLU keys, and multiplier key may all be used during a single transaction. (See X key operation below.) B. An item must be removed from the weigh pan before another item can be weighed & entered into totaling memory. The weight display must return to zero to re-set for next weighing. C. The SF/SG have automatic power off capability. If there is a long delay in the middle of a transaction ( ( , displays read 0’s.
SF/SG Series Operating Instructions 10. Calculating Correct Change for the Customer The purpose of this function is to allow the operator to determine the correct change to return to the customer once payment has been made. Example: There have been 4 entries and the total cost of the transaction is $80.00. WEIGHT ( MODE PRICE UNIT PRICE total . Displays ( Step 1: Press 4 80.00 Step 2: Enter customer payment by 10 key pad (Example: $100) Displays: WEIGHT UNIT PRICE Rece iu 100.00 PRICE 80.
SF/SG Series Operating Instructions 12. Automatic Cancellation of Unit Price In very busy applications, it may be more convenient for the Unit Price entry to return to zero after each operation. (F2 should be “0”.) To do this, press the key while the display is in normal operation. 1 CHANGE PRICE UNIT PRICE WEIGHT •ut ut • c Automatically clears unit price. TOTAL M+ PRICE UNIT PRICE WEIGHT Ut Does not automatically clears unit price.