SW Series Super Washdown Scales SW-6KS / SW-15KS SW-15KM / SW-30KM / SW-60KM / SW-150KM SW-60KL / SW-150KL 1WMPD4002080A
Warning Definition The warning described in this manual has the following meaning: DANGER An imminently hazardous situation which, if not avoided, will result in death or serious injury. © 2011 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language in any form by any means without the written permission of A&D Company, Limited.
CONTENTS 1. COMPLIANCE ..................................................................................................... 3 2. INTRODUCTION .................................................................................................. 4 3. FEATURES........................................................................................................... 4 4. PRECAUTIONS.................................................................................................... 5 4.1. Installing the scale ....
12.4. Restoring the factory set values ............................................................ 23 13. FUNCTIONS..................................................................................................... 24 13.1. Setting the parameters .......................................................................... 24 13.2. Restoring the function settings to the factory set values ....................... 24 13.3. Function list .........................................................................
1. COMPLIANCE Compliance with FCC rules Please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection against interference when equipment is operated in a commercial environment.
2. INTRODUCTION This manual describes how the SW Series Super Washdown Scales work and how to get the most out of them in terms of performance. Please read this manual completely before using the scale. 3. FEATURES The SW Series Super Washdown Scales have the following features: Dust-tight and water-tight construction, complying with IP69K. The weighing platforms and weighing pans are made of stainless steel (SUS304). The weighing platforms are designed for easy cleaning and not to collect dust.
4. PRECAUTIONS 4.1. Installing the scale DANGER • Ground the scale so that the user will not be subject to an electric shock. • The base frame is connected to the power GND (EXC-) inside the load cell. Be sure to earth ground the AC power cable. When the AC electrical outlet has no ground terminal, use the ground terminal (screw with the ground symbol) on the scale.
4.3. Cleaning the scale Do not disassemble the scale. Do not use solvents to clean the scale. The scale can be washed with water completely. 5. UNPACKING When unpacking, check whether all of the following items are included: Instruction manual SW series scale The scale components are different depending on the type of scale.
6. DESCRIPTION OF EACH PART Display Display pole AC power cable Spirit level Pole support foot Weighing pan Ground terminal (The above illustration is for scales with a display pole.) Leveling foot Display rear side Display knobs Display knobs Display stand (The above illustration is for scales with a display pole.) (The above illustration is scales with a display stand.
6.1. Display and symbols Display LED display STABLE indicator NET indicator LO OK HI pcs ZERO indicator Weighing units g STABLE NET kg ZERO oz lb ON/OFF key ON/OFF SAMPLE PRINT UNITS ZERO TARE SAMPLE key PRINT key UNITS key ZERO key TARE key Symbols Symbol Description STABLE ○ Turns on when the weight value is stable. NET ○ Turns on when the NET weight is displayed. (The tare operation is in progress.) ZERO ○ Turns on when zero is displayed.
6.2. Keys The keys are touch-sensitive. Three levels of key sensitivity are available and can be set in the function setting “key“. When set to “key 2 “ (High), the keys can be operated with a gloved finger. Key Description ON/OFF key Turns the power ON or OFF. When turned ON, the scale will be automatically set to zero (power-on zero). To turn the power OFF, press and hold the key. Note: If pressing the key does not turn the power ON immediately, keep pressing the key.
7. SETTING UP 7.1. Attaching the display pole to the base Lower part of the display pole 2 SW-M / L series with a display pole 1. Remove the weighing pan from the base. 2. Remove the 4 screws from the lower part of the display pole. 3. Insert the display pole under the base while pulling out the cable into the base and align the cable opening positions of the pole and the base. (See “3” in the illustration.) Do not pull the cable forcibly. Take care not to pinch the cable between the pole and the base.
7.2. Installing the scale 1. Select the place for installing the scale. Refer to “4. PRECAUTIONS”. 2. Adjust the level of the base, using the spirit level and leveling feet. Confirm that the bubble is in the center of the level. SW type with a display pole has an extra foot at the bottom of the pole. Adjust this foot to touch the floor after adjusting the level of the base. Leveling foot Spirit level The size and shape depends on the scale model. 3. Adjust the display angle as follows.
8. BASIC OPERATION 8.1. Turning the power ON and OFF 1. Press the ON/OFF key to turn the power ON. All the display symbols appear and the scale waits for the weight value to become stable. When the optional sealed lead acid (SLA) battery (HC-02i) is used: After all the display symbols appear, the battery capacity status is displayed for about 1.5 seconds as shown below.
8.2. Selecting a weighing unit In the weighing mode, press the UNITS key to select a weighing unit. Each time the UNITS key is pressed, the unit changes as shown below. Ib oz Ib-oz kg or g pcs Using the function setting “Ut-g”, “kg” and “g” can be switched. Ut-g 0 : To display “kg”. Ut-g 1 : To display “g”. Notes • For the SW-60K / 150K, the function setting “Ut-g” is not available and only “kg” is displayed. • Not all the units are available, depending on the area or country. 8.3.
8.4. Weight display resolution The weight display resolution is a ratio of the minimum display to the weighing capacity. The SW series has three types of weight display resolution, as shown below. Normal: High: Maximum: 1/3,000 1/6,000 or 1/7,500 (depending on the weighing capacity) 1/12,000 or 1/15,000 (depending on the weighing capacity The factory setting is the high resolution. Select the resolution that suits your own application in the function setting “re5o”.
9. COUNTING MODE Determines a unit weight (the weight of one piece) from a known sample quantity, and calculates how many pieces are on the weighing pan using the unit weight. The unit weight is maintained even if the power is turned OFF. 1. Press the UNITS Press key to select “pcs”. (“pcs” = pieces) 2. Press the SAMPLE key to enter the sample unit weight storing mode. The numerical value on the left indicates the number of samples. ZERO 3. To change the number of samples, press the PRINT key.
10. COMPARATOR Five-level, three-level and seven-level (portion weighing mode) comparators are available. Each comparator mode compares the weight value against the preset limit values and outputs the results using LEDs (yellow / green / red). When the optional comparator relay output (SW-03) is installed, the results are output as a relay signal. • Five-level comparator mode: Uses four comparator values to compare the weight value and outputs results in five levels of LOLO, LO, OK, HI and HIHI.
10.1. The formula to compare Comparison is performed using the formula listed below and the results are output.
10.2. Entering the comparator values 1. In the weighing mode, press and hold the SAMPLE key to enter the comparator value setting mode. 2. Enter the comparator values using the following keys. UNITS To shift the blinking digit to the right. PRINT To increase the value of the blinking digit by one. SAMPLE To switch the polarity. Each time the key is pressed, “-“ is turned on and off at the leftmost digit. When on, the value is negative. TARE To confirm and store the setting value. 3.
11. AUTO-TARE FUNCTION The SW series has an auto-tare function to be used with the comparator mode enabled. Using this function in check weighing, the scale automatically tares, then displays “OK” for a certain amount of sample and repeats this process for the next weighing. Start with display zero after tare operation. Place or take away objects until the comparison result will show OK.
12. CALIBRATION Adjusts the scale for accurate weighing. Calibrate the scale in the following cases. When the scale is first installed. When the scale has been moved. When the ambient environment has changed. For regular calibration. Note: Calibration can not be performed on the Legal for Trade models. 12.1. Calibration mode The calibration mode has the following three functions.
Press the UNITS to select an item key and press the TARE to execute it. key To exit from the calibration mode, press the ZERO1 key or the CAL switch. The scale returns to the weighing mode. 12.2. Gravity acceleration correction When the scale is first used or has been moved to another location, it should be calibrated using a calibration weight. But if a calibration weight is not available, the gravity acceleration correction will compensate the scale.
12.3. Calibration using a weight Prepare a weight, preferably a weight with the same value as the weighing capacity of the scale to be calibrated. Note that the calibration weight value can be changed. 1. Turn the power ON and warm up the scale for at least half an hour. Change the function setting “poff” or place something on the weighing pan to disable the auto power-off function. 2. Refer to “12.1. Calibration mode” to enter the calibration mode. The gravity acceleration value is displayed. 3.
12.4. Restoring the factory set values If the gravity acceleration value or calibration weight value is changed unintentionally, restore those values to the factory set values, as follows. 1. Refer to “12.1. Calibration mode” to enter the calibration mode. The gravity acceleration value is displayed. 2. Press the “ClrC” . . UNITS key twice to display Press twice 3. Press the TARE key to display “ClrC no” with “no” blinking. Press 4. Press the PRINT key.
13. FUNCTIONS The scale has function settings to specify the scale performance. The parameters set in the function settings are maintained even if the power is turned OFF. Parameter Item While holding down, 13.1. Setting the parameters press 1. Turn the power OFF. 2. Press and hold the TARE key and press the ON/OFF key to turn the power ON. The software version is displayed. “∗∗∗” indicates the software version number. 3. After about one second, the item is displayed. 4.
13.3. Function list Item Auto power-off function poff Parameter Description 0 Auto power-off disabled 1 Weight display resolution 0 1 2 re5o (See Note) Weighing unit 0 Auto power-off enabled Normal (1/3,000) High (1/6,000 or 1/7,500) Maximum (1/12,000 or 1/15,0 00) kg Ut-g 1 g Zero tracking 0 Zero tracking function disabled 1 Stability band 0 width 1 2 5t-b (See Note) Stability 0 detection time 1 2 5t-t Stability 0 Response speed 1 Zero tracking function enabled ±0.
Item Serial interface Response Parameter aCk 1 Reply to commands Comparator mode 0 1 2 0 1 2 3 4 5 6 0 1 Five-level Three-level Seven-level (portion weighing mode) Comparator disabled Sets comparison Compares all data conditions Compares all stable data Compares all data of ≥ +5d or ≤ -5d d = minimum display Compares stable data of ≥ +5d or ≤ -5d in kg Compares data of ≥ +5d Compares stable data of ≥ +5d Low Medium Cp-l Comparison conditions Cp Key sensitivity key 0 2 Auto-tare function
14. OPTIONS 14.1. Using the HC-02i battery The scale can be operated with a sealed lead acid (SLA) battery, available as an option. The scale (with no other options) can be operated continuously for about 90 hours with a fully charged battery. The battery will take about 15 hours to be fully charged. The battery life will vary depending on how the scale is used, the ambient temperature and so on. A battery, NP4-6 (6V, 4Ah), manufactured by YUASA, is commercially available.
1. Disconnect the AC power cable from the electrical outlet. 2. Loosen the M4 screws and remove the rear cover of the display. Note: Take care not to drop the display. 3. Connect the wires inside the display to the battery with much care so that nothing touches the keys. Note: Be sure to connect the RED wire to the positive (+ / RED) terminal and the BLACK wire to the negative (- / BLACK) terminal. Or there is a risk of explosion. 4. Install the battery into the display. 5.
14.2. SW-03 RS-232C / RELAY OUTPUT This interface allows the SW scale to be connected to an AD-8121 printer or a personal computer, and the relay outputs for comparator results are also available. When SW-03 is installed, the dust-tight and water-tight performance of the scale will be degraded. SW-03 includes an interface board, two connector cables (7 and 10 pins), two cable glands (for cable diameter 3.5 to 7.0 mm) and two screws (M3x8). 14.2.1.
1. Disconnect the AC power cable from the electrical outlet. When the battery is installed, make sure that the scale is turned OFF. 2. Loosen the M4 screws and remove the rear cover of the display. Note: Take care not to drop the display. 3. Connect the cables to the external device through the cable gland to the terminal blocks on the interface board. 4.
When connecting to an external device with hardware flow control, communication will be impossible using a cable without RTS and CTS connected. In that case, connect RTS and CTS. This will disable hardware flow control, but will enable communication. • When the connector of an external device is a D-Sub 9-pin connector, pin 7 is RTS and pin 8 is CTS. • When the AX-KO3285-320 cable is used, RTS and CTS are internally connected and the above operation is unnecessary. 14.2.2.
Circuit diagram 1 Receive data RXD 2 Transmit data TXD 3 Data set ready DSR 4 Signal ground SG 5 Shield SHLD SW is designed as DCE (Data Communication Equipment). LOLO 1 Relay output LOLO 2 Relay output LO 3 Relay output OK 4 Relay output HI 5 Relay output HIHI 6 Relay common COM LO OK HI HIHI SW inside Solid sate relay Data format S T , + 0 0 Header 0 0 0 Data . 0 0 _ k Unit g CR LF Terminator There are 4 headers for the weighing data.
Data example Weighing data “kg” (+) S T , + 0 0 1 2 . 3 4 5 _ k g CR LF Weighing data “g” (-) S T , - 0 0 0 0 1 2 3 4 _ _ g CR LF Counting data “pcs” (+) Q T , + 0 0 0 1 2 3 4 5 _ P C CR LF Out of weighing range (+) O L , + 9 9 9 9 . 9 9 9 _ k g CR LF Data output mode (prt) Command mode The scale is controlled by commands that come from an external device such as a personal computer. For details, refer to “14.2.3. Command mode”.
14.2.3. Command mode In the command mode, the scale is controlled by commands that come from an external device such as a personal computer. Command List Command Q Z T U ?H3 ?H2 ?H1 ?L1 ?L2 ?L3 Description Send data immediately. Zero the scale when the weight is stable. Tare the scale when the weight is stable. Switch the weighing unit.
Command Description When the five-level comparator mode is used: Not used Remarks H3 When the three-level comparator mode is used: Not used When the seven-level comparator mode is used: Set the level 5 upper limit value. When the five-level comparator mode is used: Set the HIHI limit value. H2 When the three-level comparator mode is used: Set the HI limit value. When the seven-level comparator mode is used: Set the level 4 upper limit value.
Command examples (“_” indicates “Space” (20H).) The examples below are for the function setting “aCk 1 “ (Reply to commands). Request the weight data. Command Q CR LF Reply S T , + 0 0 1 2 . 3 4 5 _ k g CR LF Stable positive data U S , + 0 0 0 7 . 8 9 0 _ k g CR LF Unstable positive data O L , + 9 9 9 9 . 9 9 9 _ k g CR LF ‘E’ display Zero the scale. (No reply for the function setting “aCk 0 “.
Five-level comparator mode…Send the current LO limit value. Three-level comparator mode…Not used Seven-level comparator mode…Send the current level 3 lower limit value. Command ? L 1 CR LF Reply L 1 , + 0 0 0 2 0 0 C R LF Five-level comparator mode…Send the current LOLO limit value. Three-level comparator mode…Send the current LO limit value. Seven-level comparator mode…Send the current level 2 lower limit value.
Five-level comparator mode…Set the LO limit value. Three-level comparator mode…Not used Seven-level comparator mode…Set the level 3 lower limit value. (No reply for the function setting “aCk 0 “.) Send the six-digit value excluding the polarity and decimal point. Command L 1 , + 0 0 0 2 0 0 CR LF Reply L 1 , + 0 0 0 2 0 0 C R LF Five-level comparator mode…Set the LOLO limit value. Three-level comparator mode…Set the LO limit value. Seven-level comparator mode…Set the level 2 lower limit value.
14.3. SW-04 RS-422 / 485 This interface allows a personal computer to connect and control up to 16 scales. When SW-04 is installed, the dust-tight and water-tight performance of the scale will be degraded. SW-04 unit includes an interface board, a connector cable (10 pins), two cable glands (for cable diameter 3.5 to 7.0 mm) and two screws (M3x8). 14.3.1.
The installation procedure is the same as for SW-03. Refer to “14.2.1. Installing SW03”. Set the function settings “bp5”, “btpr”, “prt”, “5if”, “adr” and “aCk” as necessary. Before using SW-04, the function setting “5if” must be set to specify whether RS422 or RS-485 is used. To connect more than one scale to a computer, set a different address to each scale using the function setting “adr”. 14.3.2.
Example of connection RS-422 Host computer Terminator (may be built in the computer). RS-485 Terminator (may be built in the computer). RDA RDB SDA SDB Host computer SW Address 01 SDA SDB RDA RDB TRM SW Address 01 SDA SDB RDA RDB TRM SW Address 02 SDA SDB RDA RDB TRM SW Address 02 SDA SDB RDA RDB TRM SW Address 16 SDA SDB RDA RDB TRM SW Address 16 SDA SDB RDA RDB TRM A B Connect TRM to RDB at the farthest SW from the host computer.
Command examples (“_” indicates “Space” (20H).) The examples below are for the function setting “aCk 1 “ (Reply to commands). The address ## = 23. Request a weight data. Command @ 2 3 Q CR LF Reply @ 2 3 S T , + 0 0 1 2 . 3 4 5 _ k g CR LF Stable data @ 2 3 U S , + 0 0 0 7 . 8 9 0 _ k g CR LF Unstable data @ 2 3 O L , + 9 9 9 9 . 9 9 9 _ k g CR LF “E” display Zero the scale. (No reply for the function setting “aCk 0 “.
15. MAINTENANCE 15.1. Notes on maintenance Do not disassemble the scale. Contact your local A&D dealer if the scale needs service or repair. Use the original packaging for transportation. Do not use organic solvents to clean the scale. Use a warm lint free cloth dampened with a mild detergent. Calibrate the scale periodically to maintain the weighing accuracy. 15.2. Error codes Overload error Indicates that an object beyond the weighing capacity has been placed on the weighing pan.
16. SPECIFICATIONS 16.1. Specifications MODEL Weighing capacity kg Minimum display Weighing capacity g Minimum display Weighing capacity lb Minimum display Weighing capacity oz Minimum display Weighing capacity Minimum display Number of samples Maximum count Minimum unit weight Repeatability (Std.
MODEL Weighing capacity kg SW-60KM SW-150KM SW-60KL SW-150KL 60 150 60 150 0.02 0.05 0.02 0.05 0.01 * 0.02 * 0.01 * 0.02 * 0.005 0.01 0.005 0.01 130 330 130 330 0.05 0.1 0.05 0.1 0.02* 0.05* 0.02* 0.05* 0.01 0.02 0.01 0.02 2100 5200 2100 5200 1 2 1 2 0.5* 1* 0.5* 1* 0.2 0.5 0.2 0.5 130 330 130 330 1 1 1 1 5 (can be changed to 10, 20, 50 or 100) pieces 120,000 pcs 150,000 pcs 120,000 pcs 150,000 pcs 0.0005 kg 0.001 kg 0.0005 kg 0.
16.2. External dimensions 0/ 60 /9 0 ° φ42.7 353.5 0/3 ●SW-6KS / SW-15KS (with a display pole) 98 AC power cable 202 179 0/ 3 ●SW-15KM / SW-30KM / SW-60KM / SW-150KM (with a display pole) 0/ 60 /9 0 ° 722.5 AC power cable 117.5 φ42.
/6 0 /9 0° 0/ 3 0 ●SW-60KL / SW-150KL (with a display pole) 722.5 AC power cable 126.5 φ42.7 481 318 ●Display with a stand attached 315 152.5 197.5 135.
GRAVITY ACCELERATION MAP Values of gravity at various locations Amsterdam Athens Auckland NZ Bangkok Birmingham Brussels Buenos Aires Calcutta Cape Town Chicago Copenhagen Cyprus Djakarta Frankfurt Glasgow Havana Helsinki Kuwait Lisbon London (Greenwich) Los Angeles Madrid 9.813 m/s2 9.807 m/s2 9.799 m/s2 9.783 m/s2 9.813 m/s2 9.811 m/s2 9.797 m/s2 9.788 m/s2 9.796 m/s2 9.803 m/s2 9.815 m/s2 9.797 m/s2 9.781 m/s2 9.810 m/s2 9.816 m/s2 9.788 m/s2 9.819 m/s2 9.793 m/s2 9.801 m/s2 9.812 m/s2 9.796 m/s2 9.
World map 49
MEMO 50
MEMO 51
MEMO 52
3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148 A&D ENGINEERING, INC. 1756 Automation Parkway, San Jose, California 95131 U.S.A.