DIGITAL BLUETOOTH THEROMETER PBT
Index 1. Introduction 1 2. Important Information Before Use 2 3. Product Identification 3 4. Description of LCD Display 3 5. Battery Installation 4 6. Changing Modes (°C/°F Switchable) 5 7. Tips for Measuring Human Temperature 6 8. Measuring Body Temperature in the Ear 7 9. Memory Function 10 10. Operating The Bluetooth Function 11 11. Care and Maintenance 14 12. Applied Standards 14 13. Error Codes 15 14. Technical Specifications 15 15. FCC Statement 16 16.
Introduction Utilizing infrared technology, this thermometer takes temperatures in seconds by measuring heat generated by the ear canal or other objects . This product conforms to the provisions of the EC directive MDD(93/42/EEC).Its advantages include: 1. Wireless communication : Bluetooth (class 2) 2. Intended use: For home, clinic, and hospital use to determine human body temperature. 3. Illuminated back-light display 4. 10 user memory 5. °C/°F switchable f unction 6. Probe cover free 7.
Important Information Before Use When using this product, please be sure to follow all the notes listed below. Any action against these notices may cause injury or affect the accuracy. 1. Do not disassemble, repair, or remodel the thermometer. 2. Be sure to clean the thermometer lens each time after usage. 3. Avoid direct finger contact with the lens. 4. No modification of this equipment is allowed. 5. It is recommended that user take 3 temperatures. If they are different, use the average reading. 6.
Product Identification Probe Tip LED (Wireless connecting indicator) Wireless Reset Key Wireless Power Button MEMORY Recall Button Power & Measure Button LCD Display Battery compartment lid Description of LCD Display Degrees of Temperature Memory Symbol and Sets of Records Smiling face Indicating temperature is lower than 38°C (100.4°F) Frowning face Indicating temperature is equal or higher than 38°C (100.
Battery Installation Low battery warning: When the battery power becomes low, the low battery symbol “ ” will appear on the display. The thermometer can still be used during this time, but the batteries should be replaced as soon as possible. If the batteries run out completely, “Lo” will be displayed along with the low battery symbol. In this case, the batteries will need to be replaced before using the thermometer again. Replacing the Battery: 1.
Changing Modes (°C/°F Switchable ) This thermometer can display result in either degrees Fahrenheit(°F) or degrees Celsius(°C). Changing °C/ °F, please make sure the device is in power on condition. Press the Power/Scan button, hold it, and then press the Memory button to toggle between °C and °F.
Tips for Measuring Human Temperature Bear in mind that the thermometer needs to have been in the room in which the measurement is taken for at least 30 minutes before use. • Some people produce different readings in their left and right ear. In order to record temperature changes, always measure a person’s temperature in the same ear. • The ear thermometer may be used by children only under adult supervision. Measurement is usually possible over the age of 6 months.
Measuring Body Temperature in the Ear 1. Remove the front cover: Remove the cover cap: Remove the cap by gently pushing it up (1) and then pulling it off forwards (2). 2. Press the Power button to switch the thermometer on. Following a successful self test, the device emits two short beeps. 3. Make sure that the sensor tip and also the ear canal are clean. As the ear canal is slightly curved, you have to pull the ear slightly up and backwards before inserting the sensor tip.
Measuring Body Temperature in the Ear • Under 1 year: Have child lay flat with the head sideways, so that the ear is facing upwards. Gently pull the ear straight back. • 1 year +: Stand behind and slightly to the side of the child/adult. Gently pull the ear up and back to straighten the ear canal. 5. You may take out the device to read the measurement result. 6.
Measuring Body Temperature in the Ear The Readings: If the temperature measurement is below 38°C, a “Smiling Face ” will be appear next to the reading. If the reading is 38°C or above, a “Frowning Face ” will be displayed.
Memory Function Memory Recall: You can recall up to 10 measurements of all currently stored measurements in memory to share with your physician or trained healthcare professional. 1. While in power on mode, press once briefly on the “Memory” button, then pass it again to show the last measurement accompanied by “ ” symbol. 2. Continue to press the “Memory” button to view the next previously stored measurement, so “ ” then all the way to “ ”. 3.
Operating The Bluetooth Function 1. Turn the ear thermometer to the back side. 2. Turn on the wireless power (From "off" to "on"), while the thermometer searches for other Bluetooth compatible devices, the LED (connection indicator) will flash. When the device connects successfully to health monitoring devices and Bluetooth-capable devices, such as a computer, PDA, or mobile phone, the LED will remain lit.
Operating The Bluetooth Function What You Need: The host computer or terminal system to run Serial Port Profile (SPP) - A personal computer with Operating system: Windows 95 or later - A Smart Phone with Android system - Others: PDA, etc. Please refer to the instruction manual of your personal computer for how to install Serial Port Profile (SPP). Bluetooth LED: FAST BLINKING: indicate this UT-302 PBT is at linking state waiting to be linked by other Bluetooth terminal system like Smart Phone.
Operating The Bluetooth Function Communications Interface: Using Bluetooth communications terms, the UT-302PBT is a slave device. To connect the UT-302PBT to a master device you must initiate the connection by first pairing with the UT-302PBT. To complete the pairing process the “0000” number must be provided to the master as the Bluetooth Pass Key (Bluetooth PIN Code). Once the pairing is complete the UT-302PBT will automatically reconnect to the master device when possible.
Care and Maintenance • Probe and Tip: Clean the probe and tip with an alcohol swab before and after each measurement. • Thermometer: Use a soft, dry cloth to clean thermometer body. Never use abrasive cleaning agents, thinners or benzene for cleaning. Do not scratch the surface of the probe lens or the display. Do not expose the thermometer to extreme temperatures, humidity, direct sunlight, or shock. Applied Standards This product conforms to the provisions of the EC directive MDD (93/42/EEC).
Error Codes When a malfunction or incorrect temperature measurement occurs, an error message will appear as described below. LCD Display Cause Solution The temperature measured is lower than 34°C (93.2°F) The temperature measured is higher than 43°C (109.4°F) The operating temperature is not in the range from 16°C~35°C (60.8°F~95.0°F) Operate the thermometer only between the specified temperature ranges. If necessary, clean the sensor tip.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
FCC Statement 6. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 7. This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance.
EMC Tables Guidance and manufacturer's declaration-electromagnetic emission The UT-302PBT Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the UT-302PBT Thermometer should assure that it is used in such an environment.
EMC Tables Guidance and manufacturer's declaration-electromagnetic immunity The UT-302PBT Thermometer is intended for use in the electromagnetic environment specified below.The customer or the user of the UT-302PBT Thermometer should assure that it is used in such an environment .
EMC Tables Recommended separation distances between portable and mobile RF communications equipment and the UT-302PBT Thermometer The UT-302PBT Thermometer monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
This device includes RF transmitter (with wireless communication) 21
A&D Company, Limited 1-243 Asahi, Kitamoto-shi, Saitama 364-8585 JAPAN Telephone: [81](48)593-1111 Fax: [81](48)593-1119 A&D INSTRUMENTS LTD. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44](1235)550420 Fax: [44](1235)550485 A&D ENGINEERING, INC. 1756 Automation Parkway, San Jose, California 95131 USA Telephone: [1](408)263-5333 Fax: [1](408)263-0119 A&D AUSTRALASIA PTY.LTD.