Operation Manual
20 Instruction manual ADMR
3.4.2 General and electrical specifications
DESCRIPTION Unit ADMR 40 ADMR 50 ADMR 60 ADMR 80 ADMR 90 ADMR 115 ADMR 135
Capacity litres 309 357 298 335 278 253 252
Maximum operating pressure bar 8 8 8 8 8 8 8
Empty weight kg 195 221 209 238 244 270 329
Heating-up time ΔT=45°C minutes30261917128 7
Number of anodes - 2 2 2 3 3 4 4
Number of bar burners/orifices -3457796
Number of flue tubes/flue baffles - 5 6 7 9 12 16 17
Electrical power consumption W 50 50 50 50 50 50 80
Supply voltage (-15% +10% VAC) volts 230 230 230 230 230 230 230
Mains frequency Hz (± 1Hz) 50 50 50 50 50 50 50
IP class - 30 30 30 30 30 30 30
DESCRIPTION Unit ADMR 40 ADMR 50 ADMR 60 ADMR 80 ADMR 90 ADMR 115 ADMR 135
Load Profile - XXL XXL XXL XXL 3XL 3XL 3XL
Energy Efficiency Class (Energy Label) - B B B B - - -
Energy Efficiency %62626161585760
Daily Electricity Consumption kWh 0,165 0,165 0,165 0,165 0,165 1,376 1,423
Daily Fuel Consumption kWh GCV 38,977 39,216 40,065 39,847 80,312 78,659 74,360
Mixed Water 40 °C (V40) ltr. 1077 ∞∞∞1105 ∞∞
Additional Load Profile - 3XL 3XL 3XL 3XL - - -
Energy Efficiency % 61 66 62 62 - - -
Daily Electricity Consumption kWh 0,180 0,181 0,182 0,183 - - -
Daily Fuel Consumption kWh GCV 75,723 70,450 75,379 74,980 - - -
Mixed Water 40 °C (V40) ltr. 615 759 761 923 - - -