Water Heater Installation Manual

33 Page
-X3™ Scale Prevenon Technology-
This water heater is equipped with X3
Scale Prevention Technology to inhibit scale formation within the
heat exchanger tubing of this unit. Part of the X3
Technology’s anti-scale protection comes from the special
X3
Cartridge media. The X3
Cartridge must be installed into the manifold located on the underside of the
heater cabinet prior to operation of the unit (shown as follows). The X3
system is designed to be hassle-free;
eliminating the need to drain the heater for installation, removal, or replacement of the cartridge. X3
Scale
Prevention Technology reduces the formation of scale in the heat exchanger, extending the operating life of the
unit in typical potable water installations. Specific water conditions may impact the efficiency of X3
, such as
excessive iron (>0.3 mg/l). Consult a water quality expert to determine if your water is within acceptable X3
and EPA guidelines.
X3
Technology Installation/Removal
Installation -
1. Align the symbol with the symbol and insert the X3™ Cartridge into the X3™ manifold
2. Turn it right until the symbol aligns with the symbol.
Removal -
1. Close the shutoff valve on the cold water supply.
2. Turn off the power supply.
3. Open a hot water fixture to relieve water pressure in the heater.
4. If a drain pan is not installed, place a bucket or pan underneath the X3™ Cartridge as some water may be
present when removing.
5. Turn the X3™ Cartridge left until the symbol aligns with the symbol.
6. Pull down to remove it from the water heater. It is normal for a small amount of water to drip. NOTE: the
cartridge will be full of water. Take care to not tilt it till you can drain the water.
INSTALLATION
REMOVAL
Installaon
Installaon Manual