Water Heater Installation Manual

55 Page
Troubleshoong
Owner's Guide
*These error codes will be cleared when water flow stops.
Controller
Green
LED
Malfunction
description
Diagnosis
311*
Two
Flashes
240HX3/340HX3:
Outlet Thermistor
Failure
540HX3: Heat
Exchanger Thermistor
Failure
Check for connection/breakage of wires and/or debris on thermistor (Part
#407, 408, 411, 715, 718, 721).
321*
Two
Flashes
Inlet thermistor failure
331*
Two
Flashes
Outlet thermistor fail-
ure (540HX3 only)
341*
Two
Flashes
Exhaust thermistor failure
(Indoor models only)
391*
Two
Flashes
Air-fuel ratio rod fail-
ure
Check for connection/breakage of wires (Part #709) and/or soot on the AFR
rod (Part #108).
510
Six
Flashes
Abnormal main gas
solenoid valve
Check for connection/breakage of wires (Part #708) and/or burn marks on the
computer board (Part #701).
551
Six
Flashes
Abnormal gas solenoid
valve
Check for connection/breakage of wires (Part #708) and/or burn marks on the
computer board (Part #701).
611*
Four
Flashes
Fan motor fault Check for connection/breakage of wires, dust buildup in the fan motor (Part #103)
and/or burn marks on the computer board (Part #701).
Check for frozen/corrosion of connectors (Part #103).
661*
Four
Flashes
Bypass valve fault
(540HX3 only)
Inspect the bypass valve (Part #403), for connection/breakage of wires, locked
motor drive due to scale buildup, and/or water leakage.
701*
One
Flash
Computer board fault Check for connection/breakage of wires (Part #714).
711*
One
Flash
Gas solenoid valve
drive circuit failure
Refer to the 111 and 121 error codes.
721*
Six
Flashes
False flame detection For indoor models, check if condensate drain is installed on the vent collar of
the water heater.
Check if there is leaking from heat exchanger (Part #401).
741
N/A
Miscommunication
between water heater
and remote controller
Check the model type of the remote controller.
Inspect the connections between the water heater and remote controller.
Check the power supply of the water heater.
751
N/A
Miscommunication
between water heater
and built-in controller
(Indoor models only)
Inspect the connections between the water heater and built-in controller.
Check the power supply of the water heater.
941
Five
Flashes
Abnormal exhaust
temperature (Indoor
models only)
Check for connection/breakage of wires, dust buildup in the fan motor (Part #103).
Check for connection/breakage of wires (Part #472, 721).
991
Five
Flashes
Imperfect
combustion
Check the gas type of the water heater.
Inspect the environment around the water heater. Determine how long the
unit has been installed.
Check the altitude/elevation of the area where the water heater is installed.
Check if there is any blockage in the intake air and/or exhaust.
If the water heater is installed as a direct-vent system, check whether there is
enough distance between the intake air terminal and the exhaust terminal.
Check if there is grease and/or dirt in the burner (Part #101) and the fan motor
(Part #103), especially if the water heater has been installed in a contaminated
area.