Operating Instructions and Installation Instructions
22 Instruction manual BFM
3.4.2 General and electrical specifications
General and electrical specifications
Description Unit BFM 30 BFM 50 BFM 80 BFM 100 BFM 120
Volume ltr. 309 298 253 253 253
Maximum operating pressure bar 8 8 8 8 8
Empty weight kg 230 245 295 320 320
Heating-up time ΔT=45°C minutes3722129 8
Diameter of air restrictor mm 36 42 54 48 64
Number of anodes - 2 2 4 4 4
Number of bar burners/orifices - 3 5 7 7 7
Number of flue tubes/flue baffles - 5 7 16 16 16
Electrical power consumption W 100 100 100 275 300
Supply voltage (-15% +10% VAC) volts 230 230 230 230 230
Mains frequency (± 1Hz) Hz 50 50 50 50 50
IP class -2020202020
Description Unit BFM 30 BFM 50 BFM 80 BFM 100 BFM 120
Load Profile - XXL XXL XXL 3XL 3XL
Energy Efficiency Class (Energy Label) - B B B - -
Energy Efficiency %6062606767
Daily Electricity Consumption kWh 0.099 0.071 0.058 0.152 0.123
Daily Fuel Consumption kWh GCV 40.324 39.327 40.539 69.917 69.799
Mixed Water 40 °C (V40) ltr. 1051 ∞∞2135 ∞
Additional Load Profile - - 3XL 3XL - -
Energy Efficiency %- 71 70 - -
Daily Electricity Consumption kWh - 0.112 0.079 - -
Daily Fuel Consumption kWh GCV - 65.936 66.772 - -
Mixed Water 40 °C (V40) ltr. - 526 662 - -