Operation Manual

10
1.6 Technical data
Device category: II2H3+
DESCRIPTION unit EQ 115 EQ 155 EQH 200
DATA NATURAL GAS G20 - 20 mbar:
Nominal load (gross) k W 9.3 11.3 18.3
Nominal capacity k W 7.4 9.0 14.0
Suppy pressure mbar 20 20 20
Burner pressure mbar 12.5 12.5 10.5
Gas consumption * m
3
/h 0.9 1.1 1.7
Diameter main orice mm 2.35 2.60 3.50
Diameter pilot orice mm 2 x 0.27 2 x 0.27 2 x 0.27
Heating time ΔT= 44 K min. 45 49 40
Emissions of Nitrogen Oxides (NO
2
) mg/kWh GCV 191 162 143
DATA BUTANE G30 - 30 mbar:
Nominal load (gross) k W 10.1 12.2 17.6
Supply pressure mbar 30 30 30
Burner pressure mbar 30 30 30
Gas consumption * kg/h 0.7 0.9 1.3
Diameter main orice mm 1.40 1.50 1.95
Diameter pilot orice mm 0.22 0.22 0.22
DATA PROPANE G31 - 37 mbar:
Nominal load (gross) k W 9.8 11.8 17.2
Supply pressure mbar 37 37 37
Burner pressure mbar 37 37 37
Gas consumption * kg/h 0.7 0.8 1.2
Diameter main orice mm 1.40 1.50 1.95
Diameter pilot orice mm 0.22 0.22 0.22
GENERAL
Storage capacity litres 109 144 181
Water connections** -
3
/
4
" - 14 NPT
3
/
4
" - 14 NPT
3
/
4
" - 14 NPT
Gas connection - ISO
7
/
1
Rp
1
/
2
ISO
7
/
1
Rp
1
/
2
ISO
7
/
1
Rp
1
/
2
Drain valve -
3
/
4
" - 14 NPT
3
/
4
" - 14 NPT
3
/
4
" - 14 NPT
Anode -
3
/
4
" - 14 NPT
3
/
4
" - 14 NPT
3
/
4
" - 14 NPT
T&P-plug -
3
/
4
" - 14 NPT
3
/
4
" - 14 NPT
3
/
4
" - 14 NPT
Maximum operating pressure bar 8 8 8
Empty weight kg 47 52 75
* Gas consumption at 1013,25 mbar and 15°C
** For a leak-proof sealed connection European coupling pieces can be used on the NPT-connection nipples with a
pipe thread of ISO 228/1