Installation Guide
Residen al Gas Water Heater Use and Care Guide for Manufactured Homes • 21
INSTALLATION
INSTALLATION
Once you’ve made the gas connec-
ons, use a small, so -bristled brush
to apply a hand dishwashing soap
and water mixture or children’s soap
bubbles (1 part soap to 15 parts water)
to all connec on points of the gas line
and fl exible gas connector (if used).
Make sure to generously coat all the
connec ons and check for gas leaks
(which will appear as small bubbles).
If any leaks are detected, turn the gas
supply off , ghten the leaking connec-
on and re-check.
BEFORE LIGHTING THE WATER
HEATER...
Make sure all checklist items have
been completed.
Water Heater Loca on
✓ Installa on area free of corrosive
or fl ammable materials, liquids or
vapors.
✓ Proper clearances from combus ble
surfaces maintained and suffi cient
room to service the water heater.
✓ Not installed directly on a carpeted
fl oor.
✓ Metal drain pan installed and piped
to an adequate drain or through the
fl oor to the outside of the structure.
✓ Water heater not located near an
air moving device (fan, clothes
dryer).
✓ Not in a loca on with large
amounts of lint, dust, etc. (If so, the
air fi lter or fl ame arrestor located
on the bo om of the water heater
will need to be cleaned more of-
ten.) See Enclosure InstallaƟ on
Requirements on page 9.
Combus on Air Supply and
Ven la on
✓ Adequate air supply for water
heater and any other nearby gas
appliances.
✓ Are the openings of suffi cient size?
✓ Ductwork is the same cross-sec on-
al area as the openings?
Vent Pipe System
✓ New dra hood, properly installed.
✓ Vent pipe (roof jack) securely
fastened to dra hood with screws
and supported properly. Follow
the roof jack manufacturer’s
instruc ons.
✓ Approved vent (roof jack).
See page 8.
✓ Vent system installed according
to local and state codes or, in the
absence of local and state codes,
the “Na onal Fuel Gas Code”, ANSI
Z223.1 (NFPA 54)-current edi on.
Manufactured home manufacturers
must conform with The Manufac-
tured Home ConstrucƟ on and Safety
Standard, Title 24 CFR, Part 3280.
✓ Check exis ng vent system for rust,
restric ons/obstruc ons.
Water System Piping
✓ Temperature and pressure relief
valve properly installed with a
discharge line that runs through
the fl oor to the outside or to an
adequate drain and is protected
from freezing.
✓ Water pipes free of leaks.
✓ Water heater completely fi lled with
water.
✓ Thermal Expansion Tank installed
✓ Water Pressure Reducing Valve
installed and adjusted to 50-60 psi.
✓ Thermosta c Mixing Valves in-
stalled at each point-of-use.
Gas Supply and Piping
✓ Gas type is the same as that listed
on the water heater’s ra ng plate
(or the same as what is listed on the
conversion label if the water heater
was properly converted).
✓ Gas line equipped with shut-off
valve.
✓ Adequate gas pipe size and ap-
proved gas pipe material.
✓ All gas connec ons and fi ngs leak
checked and any leaks corrected.