Installation Guide
8 • Residen al Gas Water Heater Use and Care Guide for Manufactured Homes
GETTING STARTED
METHOD I
ROOF JACK
(NOT INCLUDED)
ROOF
CEILING
MAINTAIN MIN. CEILING
CLEARANCE PER
DATA PLATE
MAINTAIN MIN.
CLEARANCE PER CODE
SECURE TOP
TO WALL WITH
STRAP AND
SCREWS
MAINTAIN MIN.
CLEARANCES
SECURE WATER HEATER
TO FLOOR WITH BRACKETS
AND SHEET METAL
SCREWS (PROVIDED)
FLOOR
* FREE AREA FOR AIR OPENING: 20 SQ. IN. MIN.
6 INCHES MAX.
ABOVE BOTTOM
EDGE OF DOOR
OUTSIDE
FRESH
AIR
ONE OPENING
IN DOOR *
PROTECTION:
1/4 IN. WIRE
MESH OR
LOUVERS
OPENING:
20 SQ. IN. MIN.
METAL
DRAIN PAN
ROOF JACK
(NOT INCLUDED)
ROOF
METHOD II
CEILING
MAINTAIN MIN. CEILING
CLEARANCE PER
DATA PLATE
MAINTAIN MIN.
CLEARANCE PER CODE
SECURE TOP
TO WALL WITH
STRAP AND
SCREWS
MAINTAIN MIN.
CLEARANCES
SECURE WATER HEATER
TO FLOOR WITH BRACKETS
AND SHEET METAL
SCREWS (PROVIDED)
AIR INTAKE
FLOOR
IMPORTANT: DRAIN PAN MUST
NOT BLOCK OR COVER AIR INTAKE
* FREE AREA FOR AIR OPENING: 20 SQ. IN. MIN.
FLOOR OPENING (5 IN. MIN. DIA.) *
1/4 IN. WIRE MESH PROTECTION
METAL
DRAIN PAN
Figure 3: Enclosure Configurations
GETTING STARTED
This water heater uses a non-direct,
single-pipe vent system to remove
exhaust gases created by the burning
of fossil fuels. Air for combus on
is taken from the immediate water
heater loca on or is ducted in from
the outside (see Enclosure InstallaƟ on
Requirements).
This water heater must be properly
vented for the removal of exhaust
gases to the outside atmosphere.
Correct installa on of the vent pipe
system is mandatory for the proper
and effi cient opera on of this water
heater and is an important factor in the
life of the unit.
The vent pipe must be installed
according to all local and state codes
or, in the absence of local and state
codes, the NaƟ onal Fuel Gas Code,
ANSI Z223.1 (NFPA 54)-current edi on.
Manufactured home manufacturers
must conform with The Manufactured
Home ConstrucƟ on and Safety
Standard, Title 24 CFR, Part 3280.
The vent pipe installa on must not
be obstructed so as to prevent the
removal of exhaust gases to the
outside atmosphere.
IMPORTANT:
• Do not use a vent damper anywhere
in the vent system of this water
heater.
• DO not common vent this water
heater with any other appliance.
• This water heater must have a
properly-installed dra hood and be
connected to a listed roof jack that
terminates to the outdoors. The
roof jack vent pipe must be secured
to the dra hood with sheet metal
screws. (Roof jack not furnished.)
The following roof jack models are
cer fi ed for use with this water heater
and are available from your water
heater supplier:
Field Controls No. 987 for roof pitch of
5-12 or less:
TABLE 2
KIT NUMBER MAXIMUM LENGTH
BETWEEN ROOF
AND CEILING
9002964005 12”
9002965005 32”
9002966005 60”
9002967005 95”
White Metal Products 3RJ for roof pitch
of 3-12 or less:
TABLE 3
KIT NUMBER MAXIMUM
LENGTH BETWEEN
ROOF AND
CEILING
9007941005 14”
9007942005 30”
Install the roof jack according to its
manufacturer’s instruc ons.