FEATURES AND OPERATING CYCLES
TANK SPECIFICATIONS
1
2
4
3
1. SHELL constructed of light-weight drawn steel with
powdercoat nish that provides extra corrosion-
resistance.
2. STRONG AND FLEXIBLE BUTYL DIAPHRAGM
assures dependable tank service even with
pressures up to 150 PSI.
3. DIAPHRAGM SEAL consists of locking retainer ring
for positive separation of air and water.
4. LINING protects inner shell against rust in water
reservoir.
START-UP CYCLE
The diaphragm is pressed
against the bottom of the
air chamber
FILL CYCLE
Water is pumped into the
reservoir, which forces the
diaphragm upward into
the air chamber.
HOLD CYCLE
Pump attains cut-off
pressure. Diaphragm
reaches uppermost
position. Reservoir is lled
to capacity.
DELIVERY CYCLE
Pump remains off while
pressure in air chamber
forces diaphragm
downward to deliver
water.
Figure 1. Example of How a 30-50 PSI System Works
Figure 2. Rough-In Dimensions