Operating Instructions and Installation Instructions
18
4 COMMISSIONING [INSTALLER]
Observe the following safety instructions regarding the commissioning of the station:
Attention: Risk of burns and scalding!
The valves and ttings can heat to temperatures of more than 100 °C due to
the solar uid. Therefore, do not clean or ll the installation with the collector’s
heated (intense sunshine). Observe that hot solar uid can leak from the safety
valves in case of too high system pressure!
Attention: Risk of frost!
It often happens that the solar system cannot be completely drained after
ushing. Thus, there is a risk of frost damage when ushing with water.
Therefore, do only use the solar uid used later to ush and ll the solar
system. Use a water and propylene glycol mixture with max. 50 % propylene
glycol as solar uid.
Note regarding the commissioning sequence
When putting the system into operation, rst ll the heating circuit and then
the solar circuit. This guarantees that eventually absorbed heat can also be
dissipated.