Owner manual
A.R.I. FLOW CONTROL ACCESSORIES Ltd.
www.arivalves.com ari@ari.co.il Tel: 972-4-6761899
TROUBLESHOOTING GUIDE
PROBLEM REASON SOLUTION
Discharge Outlet Leak a. Debris caught in the Rolling Seal
b. Debris caught between the Air & Vacuum
Seal and the Body.
c. Torn or cracked Rolling Seal and/or Air &
Vacuum Seal.
Perform:
PERIODIC MAINTENANCE
Discharge Outlet Broken Air valve was hit or mishandled. Unscrew and replace.
Upper Drain Outlet Upper Drain Outlet plugged with debris and
won't drain the accumulated water.
Clean the hole with a pin and clean running
water or a burst of air.
MAINTENANCE INSTRUCTIONS D-43
EnM-D43-2-12
PARTS LIST
No. Part
1. Discharge Outlet
2. O-Ring
3. Body
4. Float and Seal Assembly
4a. Air & Vacuum Seal
4b. Air Release Rolling Seal
5. Float Lock
6. Upper Drain Outlet
Upper Component
Air Release Rolling Seal
Air & Vacuum Seal
Lower Component
Float and Seal Assembly
Fig. 2
Fig. 1
4
A
B
C
4b
6
3
4a
4
2
1
5


