Instructions for Use

« Pb Battery » progam
This program allows you to charge or discharge your Lead Acid batteries.
Charge
This function allows to charge lead Acid batteries from 2 up to 20 Volts. Please input the charge current and
nominal voltage of the battery connected. Please note that Lead Acid batteries should be charged slowly, with 0.1C
charge current ( 1/10 of their total capacity). It is necessary, in most time, to disable the safety timer to avoid partial
charge.
Discharge
Same as above function, for discharging the battery.
« Program Select » Menu detail
Your charger is featuring a user memory handling up to 5 customised programs. You can save or recall these programs at any time by getting in
this menu.
Save
To save a program, select a memory slot between 1 and 5, then validate.
Choose the battery type, the voltage if necessary, and the maximum charge capacity.
Press « Enter » during 3 seconds, a « * »symbol should blink in top right of the screen.
Press Enter and select the charge current, and validate again.
For Lithium batteries, please check the number of cells and validate.
Then, press again “Enter” for 3 seconds, the message “Save” will appear for a few instants, the program is now
saved in the charger memory.
Load
This function allows you to load a previously saved program. Choose the program number you wish to load, and
press « Enter » for 3 seconds. You will then arrive to the battery charge / discharge program you had recorded in
this program.