Instructions for Use

Error messages
BATTERY CHECK HIGH
VOLTAGE
Voltage detected over the
battery voltage supposed to
be plugged in
Check the number of cells and correct if necessary
BATTERY VOLTAGE CELL
LOW
The voltage of one cell is
too low
Check the battery and battery balance. If voltage too low please
contact the battery manufacturer to ask about process to handle.
BATTERY VOLTAGE CELL
HIGH VOL
One cell has a too high
voltage
Check the battery balance and inspect carefully the battery to search
for any physical damage. Do not insist on charging and do not launch
a discharge process without contacting your battery manufacturer / distributor first.
BATTERY VOLERR CELL
CONNECT
Connection / voltage error Check all connectors and battery integrity
TEMP OVER ERR
Temperature is too high Stop any process and wait for the battery to cool down before
checking the battery.
CONTROL FAILURE
Voltage ( input / output /
check) failure
Check battery, input power supply / battery and contact imediatly
your distributor for any assistance.
REVERSE POLARITY
Polarty of battery (output) is
inverted
Check connection
CONNECTION BREAK
Battery connector is
unplugged or
malfunctionning.
Check all wires and connectors, and battery.
SHORT ERR
Short Circuit detected Check all cables / connectors and the balance connector of battery.
INPUT VOLT ERR
Input power supply voltage
error
Check the power supply, in case of use of a battery car, it might be
discharged or you might need to setup a lower input voltage low
limit. Contact your distributor for any advise or for power supply
check.
VOL SELECT ERR
The voltage you have setup
is not matching the voltage
detected by the charger for
the battery.
Check the battery and the connections, and specify correct voltage / number of cells. For Lithium
Batteries, if the voltage can not be
detected correctly by the charger, please contact the battery
manufacturer / distributor
BREAK DOWN
Hardware / software error Stop any process, disconnect the charger from power supplly and
disconnect any battery attached to the charger. Contact your
distributor technical support.