User Manual

Module Specification
NO.
AT357HPA
TITLE:
Module, ZigBee, 17.9 x 24.9 x 2.75mm, 51 I/O, Edge Castellated, SMD
REVISION DATE:
22 May 2013
ISSUE:
O
PAGE:
27 of 29
8.4 FCC Approved Power Settings
Table 15 shows approved channels of operations with the corresponding maximum
output power steps settings.
Channel 11 Channel 12-24 Channel 25 Channel 26
AT357HPA
-4dBm -4dBm -11dBm -43dBm
Table 15: Maximum Power Settings for FCC Compliance
8.5 CE Notice
The AT357HPA module has been tested and certified for use in the European Union.
If this module is to be incorporated into a product, the OEM must ensure compliance
of the final product to the European Harmonized EMC and low voltage/safety
standards. A Declaration of Conformity must be issued for each of these standards
and kept on file as described in Annex II of the R&TTE Directive. The final product
must not exceed the specified power ratings, antenna specifications and installation
requirements as specified in this user manual. If any of these specifications are
exceeded in the final product then a submission must be made to a notified body for
compliance testing to all of the required standards.
8.6 OEM Labeling Requirements
1. The CE conformity marking must consist of the initials CE taking the following form:
To satisfy FCC RF exposure requirements, a separation distance of 20cm or more
should be maintained between the antenna of this device and persons during device
operation. To ensure compliance, operation at closer than this distance is not
recommended. The antenna used for this transmitter must not be co-located or
operating in conjunction with other antennas or transmitters.