UPS Edge UPS Edge Gateway System Series User’s Manual ed 1
Copyright Notice UPS-NANO This document is copyrighted, 2019. All rights are reserved. The original manufacturer reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of the original manufacturer. Information provided in this manual is intended to be accurate and reliable.
Acknowledgement UPS-NANO All other products’ name or trademarks are properties of their respective owners. Microsoft Windows® is a registered trademark of Microsoft Corp. Intel®, Pentium®, Celeron®, and Xeon® are registered trademarks of Intel Corporation Atom™ is a trademark of Intel Corporation ITE is a trademark of Integrated Technology Express, Inc. IBM, PC/AT, PS/2, and VGA are trademarks of International Business Machines Corporation.
Packing List UPS-NANO Before setting up your product, please make sure the following items have been shipped: Item Quantity xUPS-EDxx-xxxxx-xx01 (X=0~9, A~Z, General P/N) 1 If any of these items are missing or damaged, please contact your distributor or sales representative immediately.
About this Document UPS-NANO This User’s Manual contains all the essential information, such as detailed descriptions and explanations on the product’s hardware and software features (if any), its specifications, dimensions, jumper/connector settings/definitions, and driver installation instructions (if any), to facilitate users in setting up their product. Users may refer to the AAEON.com for the latest version of this document.
Safety Precautions UPS-NANO Please read the following safety instructions carefully. It is advised that you keep this manual for future references 1. All cautions and warnings on the device should be noted. 2. Make sure the power source matches the power rating of the device. 3. Position the power cord so that people cannot step on it. Do not place anything over the power cord. 4. Always completely disconnect the power before working on the system’s hardware. 5.
17. If any of the following situations arises, please the contact our service UPS-NANO personnel: i. Damaged power cord or plug ii. Liquid intrusion to the device iii. Exposure to moisture iv. Device is not working as expected or in a manner as described in this manual 18. v. The device is dropped or damaged vi.
FCC Statement UPS-NANO This device complies with Part 15 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
China RoHS Requirements (CN) UPS-NANO 产品中有毒有害物质或元素名称及含量 AAEON Main Board/ Daughter Board/ Backplane 有毒有害物质或元素 部件名称 印刷电路板 及其电子组件 外部信号 连接器及线材 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr(VI)) (PBB) (PBDE) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ O:表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T 11363-2006 标准规定的限量要求以下。 X:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T 11363-2006 标准规定的限量要求。 备注:此产品所标示之环保使用期限,系指在一般正常使用状况下。 Preface IX
China RoHS Requirement (EN) UPS-NANO Poisonous or Hazardous Substances or Elements in Products AAEON Main Board/ Daughter Board/ Backplane Poisonous or Hazardous Substances or Elements Component PCB & Other Components Lead (Pb) O Mercury Cadmium (Hg) (Cd) O O Hexavalent Chromium (Cr(VI)) Polybrominated Biphenyls (PBB) Polybrominated Diphenyl Ethers (PBDE) O O ○ Wires & Connectors O O O O O O for External Connections O:The quantity of poisonous or hazardous substances or elements found in each o
Table of Content UPS-NANO Chapter 1 - Product Specifications .............................................................................................. 1 1.1 Product Features ............................................................................................................... 2 1.3 Specifications............................................................................................................... 2 Chapter 2 – Hardware Information....................................................
UPS-NANO Chapter 1 Chapter 1 - Product Specifications Chapter 1 – Product Specifications
1.1 Product Features UPS-NANO Intel® Apollo Lake SoC N33350, N4200 and E3900 Series (E3930, E3940, E3950) Onboard LPDDR4 Memory up to 8GB, eMMC Storage up to 64GB Gigabyte LAN x 2, HDMI x 1, DP x 1 USB 2.0 x 1, USB 3.0 x 3, USB 3.0 OTG x 1 WiFi 802.11ac, 1x1, Bluetooth 4.2® (via M.2 2230) [Intel AC9260] (optional) 4G LTE cat. 4 (via MiniPCIe) Global [Quectel EG25-Gl] (optional) AI Core Movidius Myriad X mPCIe card x 1 (optional) 1.
Memory Type Onboard Single/Dual Channel LPDDR4 UPS-NANO memory, up to 8GB BIOS SPI BIOS - 128Mb Flash Power Requirement 5V DC Only @6A Power Supply Type DC-In Power Consumption MAX 25W (Typical) Dimensions (L x W) 105 x 100 x 69,4mm (L x W x H) Operating Temperature Without power adaptor 0°C ~ 45°C (32°F ~ 113°F) With power adaptor 0°C ~ 40°C (32°F ~ 104°F) Operation Humidity 10 ~ 80% relative humidity, non-condensing Certification CE/FCC Class A, RoHS complaint
I/O UPS-NANO Ethernet Realtek RTL8111G-CG x 2 Audio HDMI I2S x 1 DP x 1 USB 3.0 OTG x 1 USB USB 3.0 x 3 USB 2.0 x 1 Antenna Antenna x 4 Power input Power button x 1 DC Power x 1 Onboard eMMC up to 64 GB Expansion Slot Mini Card (Full-size) (auto switch with mSATA) M.2 2230 Connectivity 4G 4G LTE cat.
UPS-NANO Bluetooth Bluetooth V5.0 AI Core SoC : Intel® Movidius™ Myriad™ X VPU 2485 Myriad- X Supported Frameworks :TensorFlow, Caffe interface: mini-PCI-e Minimum system requirements : x86_64 computer running, Ubuntu 16.
UPS-NANO Chapter 2 Chapter 2 – Hardware Information Chapter 2 – Hardware Information
2.
I/O Location 2.3 List of Systems Connectors UPS-NANO 2.2 Please refer to the table below to locate the I/Os represented at the point 2.2. Label Function 1 Display Port 2 HDMI 3 GbLAN Network port 1 4 GbLAN Network port 2 5 Dual USB 3.0 stack 6 Power input jack 7 Power button 8 USB 3.
UPS-NANO 12 Antenna connector 13 Antenna connector 14 Antenna connector Chapter 2 – Hardware Information
2.
UPS-NANO Chapter 2 – Hardware Information
2.5 List of Jumpers and Connectors UPS-NANO Label Function CN1 RTC CN2 POWER BUTTON CN3 RESET CN7 M.
2.5.1 RTC Battery (CN1) UPS-NANO Pin Signal 1 3.3V 2 GND 2.5.
2.5.3 Reset (CN3) UPS-NANO Pin Signal 1 RESET # 2 GND 2.5.4 M.2 E-KEY (CN7): 802.11ac, 1x1, Bluetooth 4.2® (via M.2 2230) Pin Signal Pin Signal Pin Signal 1 GND 2 3.3V 3 USB_D+ 4 3.
UPS-NANO 22 UART_RXD 23 NC 24 N/A 25 N/A 26 N/A 27 N/A 28 N/A 29 N/A 30 N/A 31 N/A 32 UART0_TXD 33 GND 34 UART0_CTS 35 PCIE_C_TXP3 36 UART0_RTS 37 PCIE_C_TXN3 38 NC 39 GND 40 NC 41 PCIE_RXP3 42 NC 43 PCIE_RXN3 44 NC 45 GND 46 NC 47 CLK_PCIE_M2_P 48 NC 49 CLK_PCIE_M2_N 50 Suspend Clock 51 GND 52 RESET # 53 PCIE_M2_CLKREQ# 54 Bluetooth Enable 55 WAKE # 56 Wi-Fi Enable 57 GND 58 SMBus_DAT 59 NC 60 SMBus_CLK 61 NC 62 SMBus_Alert
2.5.5 Mini Card (CN8) UPS-NANO Pin Signal Pin Signal Pin Signal 1 WAKE # 2 3.3V 3 NC 4 GND 5 INT_SERIRQ 6 1.5V 7 PCIE_MINI_CLKREQ# 8 NC 9 GND 10 NC 11 CLK_PCIE_MINI_N 12 NC 13 CLK_PCIE_MINI_P 14 NC 15 GND 16 NC 17 NC 18 GND 19 NC 20 3G Enable 21 GND 22 RESET # 23 PERn0_mSATA_R+ 24 3.3V 25 PERp0_mSATA_R- 26 GND 27 GND 28 1.
2.5.6 SATA (CN9) UPS-NANO Pin Signal Pin Signal Pin Signal 1 GND 2 TX+ 3 TX- 4 GND 5 RX- 6 RX+ 7 GND 8 9 2.5.
2.5.8 USB3 OTG (CN13) UPS-NANO Pin Signal Pin Signal Pin Signal 1 5V 2 USB2_D- 3 USB2_D+ 4 ID 5 GND 6 USB3_RX- 7 RSB3_RX+ 8 GND 9 USB3_TX- 10 USB3_TX+ 11 12 2.5.
2.5.10 USB 13 (CN15) UPS-NANO Pin Signal Pin Signal Pin Signal 1 5V 2 USB2_D- 3 USB2_D+ 4 GND 5 USB3_RX- 6 USB3_RX+ 7 GND 8 USB3_TX- 9 USB3_TX+ 2.5.
2.5.12 FAN (CN17) UPS-NANO Pin Signal Pin Signal 1 5V 2 GND 2.5.
L4B LAN2_LINK100# UPS-NANO 2.5.
UPS-NANO 18 GPIO19 GPIO20 19 GPIO6/SPI_1_TXD GPIO7 20 GND 21 GPIO7/SPI_1_RXD GPIO8 22 GPIO20 GPIO21 23 GPIO8/SPI_1_CLK GPIO9 24 GPIO21/SPI_1_FS0 GPIO22 25 GND 26 GPIO22/SPI_1_FS1 GPIO23 27 GPIO9/I2C0_SDA GPIO10 28 GPIO23/I2C0_SCL GPIO24 29 GPIO10 GPIO11 30 GND 31 GPIO11 GPIO12 32 GPIO24/PWM0 GPIO25 33 GPIO12/PWM1 GPIO13 34 GND 35 GPIO13/I2S_WS_SYNC GPIO14 36 GPIO25/UART_CTS GPIO26 37 GPIO14 GPIO15 38 GPIO26/I2S_SDI GPIO27 39 GND 40 GPIO27/I2S_SD
2.5.
55 I2C_SCL2_3V3 56 GND 57 I2C_SDA2_3V3 58 AVS_DMIC_DATA_1 59 GND 60 AVS_DMIC_DATA_2 UPS-NANO 2.5.16 CPLD and BIOS update (CN22) Pin Signal Pin Signal Pin Signal 1 JTAG_TCK 2 GND 3 JTAG_TDO 4 1.8V 5 JTAG_TMS 6 SPI_CS 7 SPI_CLK 8 SPI_MISO 9 JTAG_TDI 10 GND 11 SPI_MOSI 12 SPI_HOLD 2.5.
2.5.18 HDMI Dual Port (CN24) UPS-NANO Pin Signal Pin Signal Pin Signal P1 DDI0_TXP_DP_0 P2 GND P3 DDI0_TXN_DP_0 P4 DDI0_TXP_DP_1 P5 GND P6 DDI0_TXN_DP_1 P7 DDI0_TXP_DP_2 P8 GND P9 DDI0_TXN_DP_2 P10 PORT0_CLK+ P11 GND P12 PORT0_CLK- P13 CONFIG1 P14 CONFIG2 P15 DP_AUX_P P16 GND P17 DP_AUX_N P18 DDI0_TYPE_C_HPD P19 GND P20 3.
UPS-NANO Chapter 3 Chapter 3 - Drivers Installation Chapter 3 – Drivers Installation
3.1 Driver Download and Installation UPS-NANO Please follow the steps for driver downloading and installation. Step 0 – Basic setup of the system and accessories 1. Power adapter (5V/6A DC) is well connected with system and power outlet 2. Connect HDMI cable in type A male connector. make sure it's well connected with system and display 3. Connect Keyboard & mouse to control your device. 4. Connect the antennas 5. Visit the page https://wiki.up-community.
3.2 OpenVino installation UPS-NANO 1. Make sure the bios is updated to latest stable version: 2. 3. a. https://downloads.up-community.org/ to get the bios b. https://wiki.up-community.org/Bios_Update to get the procedure Install Ubuntu or Ubilinux following the instructions here: a. For Ublinux: https://wiki.up-community.org/Ubilinux b. For Ubuntu: https://wiki.up-community.org/Ubuntu The gateway is pre-validated with OpenVINO development kit, for more informations check https://software.
UPS-NANO b. #2 Extract OPENVINO on Downloads c. #3 Type: cd ~/Downloads/l_openvino_toolkit_p_2018.5.445/ d. #4 Type: sudo -E ./install_cv_sdk_dependencies.sh e. #5 Type: sudo ./install_GUI.sh f.
#7 click Next h. #8 click install UPS-NANO g.
i. #9 Finish install UPS-NANO 6. Build Sample K. #1 Type: source /opt/intel/computer_vision_sdk/bin/setupvars.sh L. #2 Type: cd/opt/intel/computer_vision_sdk/deployment_tools/model_optimizer/install_ prerequisites M. #3 Type: sudo ./install_prerequisites.
UPS-NANO N. #4 Type: cd /opt/intel/computer_vision_sdk/deployment_tools/demo O. #5 Type: ./demo_squeezenet_download_convert_run.sh P. #6 Type: ./demo_security_barrier_camera.
Q. UPS-NANO 7. #7 Type: cd ~/inference_engine_samples_build/intel64/Release/ Run demo face detection by use MYRIAD R. #1 Type: cd ~/inference_engine_samples_build/intel64/Release/ S. #2 Type: sudo su T. #3 Type: source /opt/intel/computer_vision_sdk/bin/setupvars.sh U. #4 Type: ./interactive_face_detection_demo -i "cam" -m /opt/intel/computer_vision_sdk/deployment_tools/intel_models/facedetection-adas-0001/FP16/face-detection-adas-0001.xml -d MYRIAD 8. Run demo face detection by use CPU V.
10. Run demo face detection by use HDDL ***#1~#3 Just do it once*** UPS-NANO EE. #1 Type: sudo gedit /opt/intel/computer_vision_sdk/inference_engine/external/hddl/config/h ddl_autoboot.config FF. #2 edit total_device_num ,according to your myriadx device number to edit GG.
HH. #4 Type: cd ~/inference_engine_samples_build/intel64/Release/ UPS-NANO II. #5 Type: sudo su JJ. #6 Type: source /opt/intel/computer_vision_sdk/bin/setupvars.sh KK. #7 Type: ./interactive_face_detection_demo -i "cam" -m /opt/intel/computer_vision_sdk/deployment_tools/intel_models/facedetection-adas-0001/FP16/face-detection-adas-0001.xml -d HDDL 11. Build Reset LL.
MM. #2 Type: sudo apt-get install libudev1 UPS-NANO NN. #3 Type: sudo apt-get install libudev-dev libjson-c-dev OO. #4 Type: sudo su PP. #6 Type: mkdir build QQ. #7 Type: cd build RR. #8 Type: make –j SS.
UPS-NANO 12. Run Reset TT. #1 Type: cd /opt/intel/computer_vision_sdk_2018.5.445/deployment_tools/inference_engi ne/external/hddl/hddl-bsl/build/src UU. #2 Type: sudo ./bsl_reset -i 224 *** 11100XXX : XXX is device 0-8 ,if device 0 , you should transform (11100000)2 to (224)10 VV.