82
COMMAND
NAME
DESCRIPTION
NO.
COMMAND SYNTAX
COMMAND ARGUMENT 1 ARGUMENT 2
ARGUMENT 3
ARGUMENT 4 RESPONSE
Meter 
Info
Requests meter 
configuration info:
-  full scale range 
(L/min)
-  Meter size (inches)
-  T/P option support
(Y,N)
-  4-20 mA Output #1 
configuration 
- 4-20 mA Output #2 
configuration 
7 MI MI: 1000.0,0.75,Y,V,M
1000.0 – full scale L/min
0.75 – meter size [inch]
Y – T/P supported
N – T/P not supported 
V – volumetric flow
M – mass flow
T – Temperature
P – Pressure
D – Density 
O – Off (Disabled)
Flow 
Alarms
Sets / reads the status 
of the flow alarms.
Note: High and Low limits 
for Volumetric flow 
configuration have to be
entered in fraction %FS 
notation (0.0 – 1.0). High 
and Low limits for Mass 
flow configuration have to 
be entered in the currently
active mass flow units. 
High alarm value has to 
be more than Low alarm 
value.
Alarm conditions:
Flow > High Limit = H
Flow < Low Limit = L
Low < Flow < High = N
8 FA C (flow configuration) V-volum. flow
M-mass flow
<Value>
(high limit)
<Value>
(low limit)
FAC:V,0.9,0.1
A (action delay in sec) <Value> [0-3600] FAA:<Value (sec)>
E (enable alarm) FA:E
D (disable alarm)* FA:D
R (read current 
status)
FAR:N (no alarm)
FAR:H (high alarm)
FAR:L (low alarm)
S (Read current 
settings)
FAS:M,C,H,L,D,B 
where: M – mode (E/D)
C– Configuration (V/M)
H – High settings value
L – Low settings value
D – Action Delay (sec)
B – Latch mode (0-1)
L (Latch mode)  <Value> (0-disabled*)
(1-enabl’d)
FAL:<Value> where:
Value = 0 – 1