Operating & Installation Manual RANGE OF STOVES PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK061 EN 13240:2001+ Amd. A2:2004 Rev 05 August 2009 Part No.
Congratulations on your choice of an Aarrow Stove. More than 20 years experience has been put into the development of our Ecoburn range to ensure ultimate performance and years of trouble free use and enjoyment. Every detail of the stove has been carefully designed and engineered which is why we are so confident in the reliability of our products.
Contents Page No. INTRODUCTION Page No.
WARNING IT IS A LEGAL REQUIREMENT THAT THE INSTALLATION OF ALL NEW OR REPLACEMENT, WOOD OR SOLIDFUEL HEATING APPLIANCES ARE REQUIRED TO OBTAIN BUILDING CONTROL APPROVAL FROM YOUR LOCAL AUTHORITY OR THE INSTALLATION WORK MUST BE CARRIED OUT THROUGH A GOVERNMENT APPROVED COMPETENT PERSONS SCHEME SUCH AS OPERATED BY HETAS. IF IN DOUBT, CONTACT HETAS LIMITED TELEPHONE NUMBER : 0845 634 5626 www.hetas.co.
INTRODUCTION SAFETY THE PRINCIPLE OF THE STOVE A fireguard conforming to BS 8423:2002 should be used in the presence of children and old or infirm people. Please note, this appliance should be used with the fire door closed at all times except when re-fuelling or de-ashing. Your Aarrow stove is built to the highest standard of craftsmanship using the best materials and the most modern equipment available.
CHECK LIST Inside the appliance body you should find the following: Part Description & Visual Aid (not to scale) Aarrow ECB 5 Aarrow ECB 7 Aarrow ECB 9 Aarrow ECB 11 2 2 2 2 1 1 1 1 1, ( 4" ) 1, ( 5" ) 1, ( 5" ) 1, ( 6" ) 1, ( 4" ) 1, ( 5" ) 1, ( 5" ) 1, ( 6" ) 1 1 1 1 1 1 1 1 1 1 1 1 1. Fuel Retainers 2. Throat Plate 3. Flue Spigot 4. Hot Plate 5. Ash Pan 6. Operating Tool 7.
CHECK LIST Inside the appliance you should find the following : Description & Visual Aid (not to scale) Aarrow ECB 5 Aarrow ECB 7 Aarrow ECB 9 Aarrow ECB 11 2 2 2 2 1 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 8. Side Liners 9. Rear Liners 10. Wood Burning Tray 11. Stove Mitten ( Hot Glove) 14. Fire Door Handle (Nickel Plated) Data Plate Information Data Plate Location Please Note— All Ecoburn stoves are fitted with a data plate located on the bottom right hand side of the stove.
TECHNICAL DATA Aarrow ECB 5 Aarrow ECB 7 Aarrow ECB 9 Aarrow ECB 11 Nominal Heat Output (Kw) 5.1 6.1 8.8 11 Efficiency Nett (%) 74.7 72.1 71.6 74.7 Mean Flue Gas Temperature (c) 306 363 364 370 Mean CO Emission @ 13% O2 (%) 0.58 0.58 0.68 0.71 Flue Mass Gas Flow (g/s) 4.4 4.9 6.9 6.
INSTALLATION GENERAL PRECAUTIONS HEARTH Note : All local regulations, including those referring to National and European standards need to be complied with, when installing the appliance. The Building Regulations for England and Wales 2000 ref Approved Document J 2002 edition (issued by the DTLR). The Building Standards (Scotland) (Consolidation) Regulations.
INSTALLATION FITTING THE FLUE OUTLET AND HOT PLATE The flue outlet spigot is found packed inside the appliance . The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet). Smear a very thin layer of fire cement on the mateing faces of the flue outlet and the hot plate. Fit the outlet to the appliance in the desired position.
INSTALLATION Due to the gradual introduction of Europe Chimney Standards chimneys will be specified according to their performance designation as defined in BS EN 1443 that covers the General Requirements for chimneys. The minimum performance designation required for use with solid fuel burning stoves is T450 N2 S D3. The flue and chimney installation must be carefully checked by a competent person before fitting the stove to ensure it is suitable and will work safely.
INSTALLATION NOTE - Under no circumstances should this appliance be connected to a shared flue system, that serves any other heating appliance.
INSTALLATION Typical Metal Insulated Chimney System Installed To The Chimney Manufactures Instructions In Compliance With Building Regulations And BS 7566 Part 1 to 4 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES (Plan View Of Steel Register Plate, 1.5mm Thick Minimum ) Non Combustible Register Plate. Minimum 1.5mm Thick Steel.
INSTALLATION ADJUSTING THE SELF LEVELLING FEET The Aarrow Ecoburn stoves are equipped with adjustable rear levelling feet, these are ideal for use where the hearth surface is not flat or level. Adjustment is as follows : FIREBOX LINER PANELS The Aarrow Ecoburn stoves use firebox liner panels to the sides and back. The throat plate sits on top of the sides and rear panels. These should come fitted to your stove, if however they are not, proceed as follows to fit them. Open the fire door.
INSTALLATION FINAL CHECK LIST Before handing over the installation to the customer it is a requirement under Document J that the appliance is lit and the functioning of the chimney system is checked for satisfactory operation. Fig. 3. Liners Inserted Be sure that the chimney is operating and ALL smoke and fumes are vented to the atmosphere through the chimney terminal. Check all joints and seals. Clean the outside of the appliance to prevent any stains becoming burnt on.
INSTALLATION BUILDING CONTROL CONSENT CHECKLIST Hearths, Fireplaces, Flues and chimneys This checklist is to ensure heaths, fireplaces, flues and chimneys are satisfactory, and show what you have done to comply with the requirements of the Building Regulations 2000 approved Document J 2002 1. Building address where work has been carried out …………………………………………………………………………….... …………………………………………………………………………………………………………………………. 2. Identification of hearth, fireplace chimney or flue 3.
SERVICE & MAINTENANCE ANNUAL MAINTENANCE It is important that your appliance is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following : CLEANING Important; Under some circumstances soot can quickly build up on the throat plate and adjacent areas. The throat plate should be removed and checked monthly, and any debris stripped off. Similarly, clean the upper surface of the firebox.
SERVICE & MAINTENANCE SUMMER STORAGE / NON USAGE Please ensure that your stove is left clean and moving components are well lubricated for the summer months (during periods of prolonged non use). If possible store the throat plate outside of the stove, check all moveable components, at regular intervals, to ensure they are moving freely. Refit the door and check. Please Note : There is no adjustment to the door lock / catch assembly.
SERVICE & MAINTENANCE FIRE DOOR ROPE REPLACEMENT FIRE DOOR GLASS REPLACEMENT Periodically, visually check over the fire door rope seal for any damage, cuts or tears and any detached sections. The rope gasket can be replaced, using the universal rope kit (see spare parts guide Page 32), please follow the instructions below : In the event of the door glass being broken it can easily be replaced.
SERVICE & MAINTENANCE FIRE DOOR PRIMARY AIR INLET Once a year inspect the primary air inlet assembly located at the base of the fire door. Fig. 10. Positioning The Glass Lift the door assembly from the stove body and place on a level, work bench, with the rear face upper most. Remove the 2x no. fixings. Working from the front, withdraw the oval assembly from the door casting. Clean the air slots within the door casting and slider plate.
SERVICE & MAINTENANCE Service Record Date of Visit Company Work Carried Out Signature Should you have any questions about your Aarrow Ecoburn stove that are not covered in this manual please contact your Aarrow dealer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits so they can complete the service record chart.
OPERATING INSTRUCTIONS FUEL TYPES SAFETY NOTICE The most efficient use of this appliance is with the fire door(s) closed at all times, apart from re-fuelling (when alight) or cleaning (when cold). NEVER leave the appliance unattended for an extended length of time with the door(s) open. If this is the case, a spark guard must be used and the operating efficiency of the appliance will decrease. WOOD— Any type of wood is suitable provided it is well seasoned and has a moisture content below 20%.
OPERATING INSTRUCTIONS BURNING WOOD Set the fire; by using rolled up newspaper and lay a layer of dry kindling wood on top of this. Use 2 or 3 fire lighters to light the kindling. Set the primary air and air wash controls to fully open position. See page 26. After the kindling has caught light, leave the fire door ajar by about 20mm. This will aid flue draw. The flue draw should be established after 5 Minutes, and the kindling well burnt down to form an ember bed.
OPERATING INSTRUCTIONS OVER FIRING & CHIMNEY FIRES DO NOT over fire your appliance. Using flammable liquids or too much wood or firing the stove at maximum for prolonged periods may result in overfiring. If the chimney connector or casing glows red the appliance is being over-fired this may result in a chimney fire. If this occurs : Call the Fire Service—Dial WARNING : The ash can be very hot. Empty only into a metal container.
OPERATING INSTRUCTIONS AIR INLET CONTROLS AIR WASH SYSTEM The Aarrow Ecoburn stoves have two air inlet controls. The primary air inlet providing under draught to the base of the fire chamber through the control slider located under the oval at the base of the fire door. The air wash system, (secondary air) so called because its pre-heated high speed air, washes across the inner face of the door glass, keeping it clear. This also provides an over draught to the fuel bed.
OPERATING INSTRUCTIONS MULTI PURPOSE OPERATING TOOL Your Aarrow EcoBurn stove is supplied with a multi purpose operating tool, used for adjusting the air inlet controls and the removal of the ash pan ( See fig. 17 ) TO EMPTY THE ASH PAN The Ecoburn stoves are supplied with a unique ash pan. To empty or remove the ash pan, open the fire door(s), fit the fork end of the operating tool into the ash pan slots and remove from the ash pit chamber.
OPERATING INSTRUCTIONS MAIN FIRE DOOR HANDLE A stove mitten is supplied with your Aarrow Ecoburn stove, this is provided for the operation of the fire door handle whilst the stove is in use. Care must be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot. WARNING : Never attempt to open the fire door whilst the appliance is in use WITHOUT the use of the stove mitten or suitable gloves, serious injuries may occur.
OPTIONAL EXTRA / ACCESSORIES Aarrow ECB 5 Aarrow ECB 7 Aarrow ECB 9 Aarrow ECB 11 Aerosol Touch Up Paint AFS 101a AFS 101a AFS 101a AFS101a Gothic Door Tracery ECB 5 ECB 7 ECB 9 TRACE G TRACE G TRACE G ECB 9 TRACE G Lattice Door Tracery ECB 5 TRACE L ECB 7 TRACE L ECB 9 TRACE L ECB 9 TRACE L Add In Slab Boiler *** AIB 0 AIB 8 AIB 9 AIB 10 Floor Fixing Kit AFS1135 AFS1135 AFS1135 AFS1135 Stands * ECB 5 STAND ECB 7 STAND ECB 9 STAND ECB 11 STAND Add On Low Canopy AOC XSL AOC
SPARE PARTS LIST PLEASE NOTE : The serial number of your stove can be found stamped into the casing , centrally between the bottom edge of the fire door aperture and the top edge of the ash pit aperture.
SPARE PARTS LIST Aarrow ECB5 Aarrow ECB7 Aarrow ECB9 Aarrow ECB11 AFS008 AFS008 AFS008 AFS008 Replacement Glass Kit AFS1214 AFS1215 AFS1216 AFS1216 Replacement Glass Rope Gasket & Clips (Universal Length) AFS1365 AFS1365 AFS1365 AFS1365 Hinge & Fixing Kit AFS047 AFS047 AFS047 AFS047 Fire Door Rope Kit Complete With Glue AFS1021 AFS1021 AFS1021 AFS1021 Fire Door Assembly, Complete AFS1218 AFS1219 AFS1220 AFS1220 Fire Door Handle Assembly AFS1306 AFS1306 AFS1306 AFS1306 R
SPARE PARTS LIST Aarrow ECB5 Aarrow ECB7 Aarrow ECB9 Aarrow ECB11 Replacement Stove Mitten ( Hot Glove ) AFS1285 AFS1285 AFS1285 AFS1285 Replacement Primary Air Inlet Slider AFS1368 AFS1369 AFS1369 AFS1369 Replacement Air wash knob AFS1405 AFS1405 AFS1405 AFS1405 Wood Burning Tray AFS 1196 AFS 1197 AFS 1198 AFS 1483 PART DESCRIPTION Aarrow Ecoburn Stoves Visual Aid (not to scale) 31
GUARANTEE Guarantee Once again we would like to thank you for buying an Aarrow Ecoburn stove. When you buy an Aarrow stove, you are not only buying a first class appliance you are buying a commitment from us to look after you and your appliance for as long as you want.
Lifetime Guarantee For your peace of mind Aarrow stoves gives a Lifetime Guarantee against manufacturing defects of the main body* Of its Ecoburn range of stoves. Additionally, all other parts are covered by a one year no quibble replacement guarantee. This guarantee covers replacement of the item only and does not extend to any other costs, including labour, incurred in its replacement. Documentation must be retained and produced in the event of a warranty claim.
Final Factory Check list Stove Model …………….……………… Serial No. ………………………………. Quality / Finish I’ve checked it and its O.K ! Parts Wood Tray Flue Outlet Hot Plate Assembled By……………………. Fuel Retainers x 2 Firebox Liners Checked by……………………….. Throat Plate Door Catch/Nickel Door Handle Convector Kit Fixings x 4 Ash Pan Adjusting Feet x 2 Operating Tool Operating & Installation Manual Stove Mitten Date of Purchase……………………………….. Name and Address of Supplier……………………………………………………………...