Operating & Installation Manual Wood / Multifuel Model Range Ecoburn 7 Multifuel PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE BK043 Rev 6 October 2006 AFS1221
Congratulations on your choice of an Aarrow Stove. More than 20 years experience has been put into the development of our Ecoburn range to ensure ultimate performance and years of trouble free enjoyment. Every detail on this stove has been carefully engineered and designed which is why we are so confident in the reliability of our product that we offer a Lifetime Guarantee.
CONTENTS INTRODUCTION Warning Notice Page 4 Safety Notices 5 The Principle Of The Fire 5 Check List 6-7 Fire Door Glass 23 Service Record 24 OPERATING INSTRUCTIONS Fuel Types 25 Lighting The Fire 25 Solid Fuel Burning 26 Burning Wood 26 Technical Data 8 INSTALLATION General Precautions 9 Handling 9 Mixed Fuels 26 Hearth 9 Anthracite 26 Combustible Materials 9 Overnight Burning 26 Air For Combustion 9 Air Inlet Controls - Primary Air 27 Fitting the Flue Outlet & Hotpla
WARNING TO ALL MULTIFUEL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES ARE "CALCO", "PETROCOKE" OR "WONDERCO" MUST NOT BE BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www.solidfuel.co.uk THE USE OF SPARE PARTS OTHER THAN THOSE SUPPLIED BY AARROW FIRES WILL INVALIDATE THE APPLIANCE GUARANTEE.
INTRODUCTION SAFETY A fireguard conforming to BS 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to BS 3248 should be fitted. Caution Do not use aerosol sprays or any other flammable materials near the appliance under fire. Do not fit an extractor fan in the same room as the appliance.
CHECK LIST Part Description ECB 5 ECB 5 ECB 7 & Visual Aid Wood Multifuel Wood (not to scale) ECB 7 ECB 9 Multifuel Wood ECB 9 ECB 11 ECB 11 Multifuel Wood Multifuel 1. Grate bars N/A 5 N/A 7 N/A 9 N/A 11 1 N/A 1 N/A 1 N/A 1 N/A 1 1 1 1 1 1 1 1 2. Wood burning tray 3. Stainless Steel Throat plate 4.
CHECK LIST Part Description ECB 5 ECB 5 ECB 7 & Visual Aid Wood Multifuel Wood (not to scale) 8. Rear grate bar support 9. Comb assembly consisting of comb & comb extension bar ECB 7 Multifuel ECB 9 Wood ECB 9 ECB 11 ECB 11 Multifuel Wood Multifuel N/A 1 N/A 1 N/A 1 N/A 1 N/A 1 N/A 1 N/A 1 N/A 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 10. Fuel retainers 11.
TECHNICAL DATA TECHNICAL DATA Room Min/Max Room Heater Only Output (kW) ECB 5 Wood ECB 5 Multifuel 1-5 1-5 ECB 7 ECB 7 ECB 9 ECB 9 ECB 11 ECB 11 Wood Multifuel Wood Multifuel Wood Multifuel 1-7 1-7 2-9 2-9 2.5 - 11 2.5 - 11 Room Heater with Domestic Hot Water with add in boiler type 0 0 8 8 9 9 10 10 Max Output to Room (kW) 3 3 4.8 4.8 6.7 6.7 7.6 7.6 Max Output to Water (kW) 2 2 2.2 2.2 2.3 2.3 3.4 3.
INSTALLATION GENERAL PRECAUTIONS Note - All installations must conform to the appropriate building regulations. The Building Regulations for England and Wales 2000 ref Approved Document J 2002 edition (issued by the DTLR). The Building Standards (Scotland) (Consolidation) Regulations. Detailed recommendations for installation of appliances, chimneys and flues are outlined in the current issue of the following British Standards:BS6461, BS8303 and BS4543.
INSTALLATION FITTING THE FLUE OUTLET AND HOT PLATE The flue outlet spigot is found packed inside the appliance. The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet). Smear a very thin layer of fire cement on the faces of the flue outlet and the blanking plate. Fit the outlet to the appliance in the desired position .
INSTALLATION Due to the gradual introduction of European Chimney Standards chimneys will be specified according to their performance designation as defined in BS EN 1443 that covers the General Requirements for chimneys. The minimum performance designation required for use with solid fuel burning stoves is T450 N2 S D3. The flue and chimney installation must be carefully checked by a competent person before fitting the stove to ensure it is suitable and will work safely. If the chimney is old (i.e.
INSTALLATION Fig. 2.
INSTALLATION TYPICAL METAL INSULATED CHIMNEY SYSTEM TO BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1-4 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES A is minimum clearance for non-insulated flue = 1.5 x D to a non-combustible surface/material or 3 x D to combustible surface/material Fig. 3.
INSTALLATION ADJUSTING THE SELF LEVELLING FEET WOOD STOVE VERSION WOOD TRAY The Aarrow Ecoburn Wood and Multifuel stoves are equipped with adjustable rear levelling feet, these are ideal for use where the hearth surface is not flat or level. The wood burning tray should come fitted in your stove, if not please follow these instructions - Adjustment is as follows: • Position the stove on the hearth into its final resting place, ensuring room for the flue connections etc.
INSTALLATION MULTIFUEL STOVE VERSIONMULTIFUEL GRATE GRATE The grates in the Aarrow Ecoburn multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb". All bars in the grate are identical, but every other bar is turned through 180 degrees, with the ends of the bars marked "H" sitting on the high sections of the comb, and the ends marked "L" sitting on the low sections. ASSEMBLING THE GRATE Fig. 7.
INSTALLATION FIREBOX LINER PANELS The Aarrow Ecoburn Wood and Multifuel stoves use firebox liner panels to the sides and back of the firebox. The throat plate sits on top of the side and rear panels. These should come fitted to your stove, if however they are not proceed as follows to fit them as follows •Open the fire door. •Remove the two round front fuel retaining bars, by lifting one end free of the bracket and sliding the remaining end out from the bracket. Fig. 10.
INSTALLATION OPTIONAL ADD IN BOILERS supplier will be able to offer advice and assistance. Aarrow Ecoburn Wood and Multifuel stoves offer the option of a slab boiler, which occupies the position of the rear firebox liner panels. Direct Systems Fitting: •Remove the fuel retainering bars, rear firebox liner panels and throat plate. •Knock out the blanking discs in the back plate corresponding to the terminals on the boiler.
INSTALLATION Primary flow and return pipes should be 28mm diameter. The cylinder should be installed at a higher level than the appliance, and as close to it as possible (the higher the cylinder the faster the circulation). The flow and return pipes should not be longer than 20ft each. Pipe runs should rise continually from the boiler to the cylinder. A radiator of approximately 25 sq.ft.
INSTALLATION CHECKLIST Hearths, Fireplaces, Flues and chimneys This checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory, and to show what you have done to comply with the requirements of The Building Regulations 2000 Approved Document J 2002. 1. Building address, where work has been carried out....................................................................................................................................... ....................................................
SERVICING & MAINTENANCE CLEANING INTERNAL SURFACES IMPORTANT Under some circumstances soot can quickly build up on the throat plate and adjacent areas. The throat plate should be removed and checked monthly, and any debris stripped off. Similarly, clean the upper surface of the firebox. Refer to page 16 for instructions on the throat plate removal / inspections. OUTER FINISH The outside finish of the appliance is a durable high temperature paint.
SERVICE & MAINTENANCE ANNUAL MAINTENANCE It is important that your fire is regularly serviced in accordance with these instructions. This should be carried out at least annually by a qualified person and should consist of the following. Remove the fire lining(s), and throat plate, inspect all gasketing on doors, glass etc. and re-order any items that may need replacing, from your Aarrow dealer.
SERVICING & MAINTENANCE DISASSEMBLE AIRWASH The Aarrow Ecoburn air wash may be disassembled for cleaning or adjustment. To achieve this, the following procedure should be followed: Note - This should only be carried out when the fire is cold and unlit. •Unscrew (Anti-clockwise) the airwash control knob (Fig. 14). •Move outer cover up by tapping each end of the cover with a soft mallet. Fig. 16. Inner slider removal •Lift outer cover free from body, being careful not to damage the ends of each lug (Fig.
SERVICING & MAINTENANCE FIRE DOOR GLASS In the event of the door glass being broken it can easily be replaced. Note: This operation should only be carried out when the appliance is unlit and cold. •Replace the four retaining clips and bolts. Do not over-tighten the bolts as damage may occur to the glass (Fig.19) Re-place the door carefully over the hinges and slot in place. •The door should be lifted off the hinges so that the operations can be carried out on a workbench or similar level surface.
SERVICING & MAINTENANCE Date of Visit Company Work Carried Out Signature Should you have any questions about your Ecoburn stove that is not covered in this manual please contact your Aarrow Fires retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart.
OPERATING INSTRUCTIONS FUEL TYPES Wood- Any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months in the case of soft woods, and at least eighteen months in the case of hard wood. We recommend that for general burning, wood should be split into logs of no more than 130mm (5") diameter. Larger logs can be used for overnight burning.
OPERATING INSTRUCTIONS ENSURE THAT YOU HAVE READ & UNDERSTOOD THESE INSTRUCTIONS BEFORE LIGHTING THE FIRE. ALWAYS WEAR SUITABLE PROTECTIVE FIRE GLOVES WHEN REFUELLING YOUR STOVE. SOLID FUEL Version Only) BURNING (Multifuel •Set the grate to ‘coal’ position. •Ensure that the ash pan is in position and the fire doors are closed. •Set the air wash (secondary air) to one quarter open position.
OPERATING INSTRUCTIONS AIR INLET CONTROLS Both Aarrow Ecoburn wood & multifuel stoves have two air inlets: •The primary air inlet providing under draught to the base of the fire chamber through the control slider located under the oval cover. •The air wash system (so called because its pre-heated high speed air washes across the inner face of the door glass, keeping it clear), which provides over draught.
OPERATING INSTRUCTIONS MULTI-PURPOSE TOOL OPERATING Your Aarrow stove comes with a multi-purpose operating tool, which is used for riddling, setting the multifuel grate *, (fuel position) , adjusting the air wash control knob and for the removal of the ashpan.
OPERATING INSTRUCTIONS MAIN FIRE DOOR HANDLE A stove mitten is supplied with your Aarrow Ecoburn stove, this is provided for the operation of the fire door handle whilst the stove is in use. Care must be taken when opening and closing the fire door as any surrounding areas of the stove will be very hot. Warning : Never attempt to open the fire door whilst the appliance is in use, without the use of the stove mitten or suitable gloves, serious injuries may occur.
OPTIONAL EXTRA / ACCESSORIES ECB 9 ECB 9 ECB 11 ECB 11 Wood Multifuel Wood Multifuel Optional Extra Description ECB 5 ECB 5 ECB 7 Wood Multifuel Wood Aerosol Paint AFS 101a AFS 101a AFS 101a AFS 101a AFS 101a AFS 101a AFS 101a AFS 101a ECB5 TRACE G ECB5 TRACE G ECB7 TRACE G ECB7 TRACE G ECB9 TRACE G ECB9 TRACE G ECB9 TRACE G ECB9 TRACE G ECB5 TRACE L ECB5 TRACE L ECB7 TRACE L ECB7 TRACE L ECB9 TRACE L ECB9 TRACE L ECB9 TRACE L ECB9 TRACE L AIB 0 AIB 0 AIB 8 AIB 8 AIB 9 AIB
SPARE PARTS LIST Part Description ECB 5 ECB 5 ECB 7 & Visual Aid Wood Multifuel Wood (not to scale) ECB 7 ECB 9 Multifuel Wood ECB 9 ECB 11 ECB 11 Multifuel Wood Multifuel 1.
SPARE PARTS LIST Part Description ECB 5 ECB 5 ECB 7 & Visual Aid Wood Multifuel Wood (not to scale) ECB 7 Multifuel ECB 9 ECB 9 ECB 11 ECB 11 Wood Multifuel Wood Multifuel 8. Liner Set 9.
SPARE PARTS LIST Part Description ECB 5 ECB 5 ECB 7 & Visual Aid Wood Multifuel Wood (not to scale) 17. Fire Door Rope Kit Complete With Glue 18.Main Fire Door Assembly, Complete With Handle, Glass, Gaskets, Clips & Seal 19.
GUARANTEE Guarantee Once again we would like to thank you for buying an Aarrow Ecoburn stove. When you buy an Aarrow stove, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance for as long as you want. The Ecoburn stoves come with a Lifetime Guarantee USE OF SPARE PARTS OTHER THAN THOSE SUPPLIED BY AARROW WILL INVALIDATE THE APPLIANCE WARRANTY.
Lifetime Guarantee For your peace of mind Aarrow Fires gives a Lifetime Guarantee against manufacturing defects of the main body* of its Ecoburn range of stoves. Additionally, all other parts are covered by a one year no quibble replacement guarantee. This guarantee covers replacement of the item only and does not extend to any other costs, including labour, incurred in its replacement. Documentation must be retained and produced in the event of a warranty claim.
FINAL FACTORY CHECK LIST Model.................................. Serial No............................. QUALITY FINISH I’ve checked it and it’s O.K. PARTS FLUE OUTLET HOT PLATE FUEL RETAINERS GRATE BARS / WOODBURNING TRAY FIREBOX LININGS Assembled by............................. THROAT PLATE Checked by ................................