12 Environmental Conditions
12.1 General
MX-ONE consists of different components as well as commercial
server-based products.
MX-ONE is designed to operate in and comply with regulations in force
for enterprise (light industry) locations. Special measures may be
required if MX-ONE is installed in other locations or if the environmental
parameters deviate from the values described in this document or in
other referenced documents.
12.2 Climatic Environment
Table 6 Temperature Range and Humidity
Product In Operation Storage
MX-ONE Slim or ASU Server
a
MX-ONE Lite
MX-ONE Classic
MX-ONE Classic Fan unit
Media gateways supported by
MX-ONE 5.0 but not available for new
deliveries:
Enterprise Media Gateway (EMG)
Media Gateway Classic
Temperature
range
+5º C to + 40º C
IEC 60068-2-1,
-2, -14 and -56;
ETSI EN 300
019-2-3 Class
3.1, Table 1,
Normal climatic
limits
-5º C to +55º C
IEC 60068-2-1,
-2 and -56; ETSI
EN 300019-2-1
Class 3.1, Table
1
Relative
humidity
+5% to 85% IEC
60068-2-1, -2,
-14 and -56; ETSI
EN 300 019-2-3
Class 3.1,
Normal climatic
limits (no
condensation)
Maximum +95%
ETSI EN
300019-2-1
Class 3.1
(condensation)
AC/DC power unit - stand-alone (not
built-in)
As specified by
supplier
As specified by
supplier
Limits for a non Aastra server, e.g.
DELL server(model R320)
Refer to suppliers documentation for
details
Temperature
range
+10º C to +35º C -40º C to +65º C
Relative
humidity
20% to 80%
noncondensing
5% to 95%