User's Guide
Aaton
Camera body
44
Firmware Install
To update the firmware, copy the new Penelope_Vx.xx.flb file onto a USB
key (FAT32 formatted), and plug the key into the USB socket.
Power-up the camera electronics with the «on/off» key.
When the USB key is recognized, a disk icon appears on the main screen.
Select the LoadSoft item and press the «right» key to access it. Select the
version by pressing the «left» or «right» key, and wait for 2 seconds to see the
complete version names scrolling. Press «set» to validate.
The messages Loading, Prog Start, Erasing, Programming, and Success
will successively appear, and then the final one: Please Shutdown.
Shut the camera down by pressing the «on/off» key for four seconds, then
power-up again, the new software is installed.
NOTE1: it is STRONGLY RECOMMENDED to install freshly charged batter-
ies before starting the install process. If the camera looses power before it
has completed loading the new software, the unit will have to be returned for
repair.
NOTE2: do NOT power down the camera until you are told to.
NOTE3: following a firmware installation, at camera start up a message
might appear indicating an automatic update of both the motor and logic
boards.