Residential Steambath Generator Systems Installation, Operation & Maintenance Manual h t i w e Leav wner o Home aquabrass.
Residential Steambath Generator Systems Table of contents S elect Your Aquasteam Model . . . . . . . . . . . . . . . . . .2 B efore Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 S team R oom Guidelines . . . . . . . . . . . . . . . . . . . . . . . .3 Locating the S team Generator Unit . . . . . . . . . . . . . . . . .4 Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Steambath Generator Systems ______________________________ MODEL NO. ______________________________ SERIAL NO. MODELS: ABSC02787 7.5 KW 240V 1ph generator _____________________________________ ABSC02789 9 KW 240V 1ph generator _____________________________________ ABSC02782 12 KW 240V 1ph generator _____________________________________ ! WARNING REDUCE THE RISK OF OVERHEATING AND SCALDING 1. EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY OR SLEEPY.
Residential Steambath Generator Systems Select your aquasteam Model 1. Measure the Length, Width, & Height (in ft.) of steam shower or tub/shower being used. Multiply the Length x Width x Height to get the B asic R oom Volume in CUB IC FEET L _______ x W _______ x H _______ = a 2.
Residential Steambath Generator Systems Before Installing IMPORTANT: The following general information should be used in conjunction with consultations with your architect, designer and contractor in determining all factors necessary in providing a suitable and safe steam room. R ead these instructions before installation or service. Although this steambath generator has been qualified for shipment, the following must be reviewed for proper, safe and enjoyable steam bathing.
Re s i de n t i a l St e a m ba t h Ge n e r a t or Sy s t e m s L oc a t i n g t h e St e a m Ge n e r a t or U n i t Select a location as near as practical and outside the steam room. Typical locations include: closet, vanity cabinet, heated attic or basement. 1. Locate steambath generator within 25 feet (7.6 m) of steam room. 2. Do not install steambath generator inside steam room. 3.
Residential Steambath Generator Systems Installation Plumbing All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes. Use unions on all pipe connections. Use only brass piping or copper tubing as permitted by codes. Do not use black, galvanized or PVC pipe. Water Supply (3/8” NPT) 1. Connect hot or cold water line. Hot water line is preferable, however hot water should not exceed 160˚F (70° C). 2.
Residential Steambath Generator Systems Generator Dimensions /---------------------------------\ Safety Valve Optional Automatic Drain Manual Drain Valve /-----------\ A J /----- L---\ 12” /----------- G ---------\ /---------------- (305mm) C D /----- F ----\ /------------------------------------------------------------ K-----------------------------------------------------------\ /--------------\ B /------------------------------------------------------------------------------\ Steam Outle
Residential Steambath Generator Systems Electrical Specifications All electrical wiring to be installed by a qualified licensed electrician in accordance with National E lectrIcal Code and local electrical code. Power Wiring See “ Field Power Wiring” Diagrams (Page 8) 1. Check power voltage. Use 240V/ 1ph to connect S H aquasteam residential steambath generator. 2.
Residential Steambath Generator Systems Models ABSC02787, ABSC02789 (single phase wiring shown) Contactor L L, N Ground to be field wired N ! caution TO AVOID E QUIPME NT DAMAGE DO NOT CONNE CT POWE R SUPPLY DIR E CTLY TO HE ATING E LE ME NTS !!! Knock-out (fitting omitted for clarity) Ground Ground Lug (behind probe) Note: For illustrative purposes only. Consult with qualified licensed electrician for electrical installation.
Residential Steambath Generator Systems Optional Automatic Drain System (2) Pin Connector for Automatic Drain BOX CONTENTS: Automatic Drain Valve with Cord Installation instructions. Operation The optional Automatic Drain feature automatically drains the Aquasteam system following each use. The stainless steel tank is flushed and remains empty until the steam generator is used again. A time delay allows the water to cool down before it drains resulting in a safe and gentle operation.
Residential Steambath Generator Systems Installing the Aquasteam In-Shower Temperature Probe ! caution The R emote Temperature Probe is for use with aquasteam in-shower controls. Controls only. Do not use any other controls. Do not use any other temperature probe with the aquasteam in-shower controls. Noncompatible products may result in an inoperative control and a hazardous condition. ! caution Install the aquasteam control according to the installation and operation instructions.
Residential Steambath Generator Systems 5. R oute the end of the temperature probe cable with the temperature probe through the wall into the steam room as shown in Diagram 3. IMPORTANT NOTE: Do not strain, staple, pinch or otherwise damage the probe cable. 6. With a minimal length of the cable exposed apply silicone (provided) to the hole in the wall as required to create a moisture seal as shown in Diagram 3. 7. Push the temperature cable and bulb into hole as required to leave minimum 1/4 in.
Residential Steambath Generator Systems Step 1 2 5/8 " 67 mm Installating the In-Shower Control 1" 1" 25 mm 25 mm IMPORTANT: Turn power to the steam generator OFF before installing the control. Failure to turn the power offwill result in an inoperable control. Step 1 Determine the desired installation location of the control. The aquasteam control is designed to be installed inside or outside the steam room as a matter of personal preference. The control cable length is 30 ft.
Residential Steambath Generator Systems Connection of Aquasteam Control & TemperatureSensor Temp Probe Main Control Note: Valve should be closed when automatic drain is not installed 13 aquabrass.
Residential Steambath Generator Systems Operation of the In-Shower Control On/Off Key ON/OFF K ey is used to turn the steam generator on/off. Press On/Offkey to turn steam generator on. Press a second time to turn steam generator off. A built-in timer automatically shuts the steam generator offa predetermined period of time after it has been started, unless the user does so manually. The "Display" indicates the S et Point temperature.
Residential Steambath Generator Systems Replacement Parts Diagram aquasteam shown with access cover removed for clarity Contactor Liquid Level Circuit Board Water FeedSolenoid Transformer Power Supply Knock-out Water Feed Liquid Level Probe Plugand Play Connection Steam Outlet Safety Valve Note: For illustrative purposes only. S ome Access Cover components may be omitted or altered for clarity.
warranty Residential Steambath Limited Lifetime Warranty aquasteam extends to the original consumer purchaser of a aquasteam. RESIDENTIAL STEAMBATH GENERATOR (aquasteam Generator), installed in the United States or Canada (excluding controls and accessories), a warranty that such aquasteam Generator is free from defects in materials and workmanship. aquasteam will repair or replace at its option a Generator if it fails to conform to this warranty.
residential steambath generators and control by aquabrass aquabrass.