Owner`s manual

Power block
Fuse block
Contactor
Fuse
Ground lug
Knock-out
(conduit and fittings
omitted for clarity)
L2
L1
Ground
Residential Steambath Generator Systems
8
Models ABSC02787, ABSC02789
(single phase wiring shown)
L,NGroundtobeeldwired
TO AVOID EQUIPMENT DAMAGE
DO NOT CONNECT POWER SUPPLY
DIR E CTLY TO HE ATING ELE ME NTS !!!
Note:
For illustrative purposes only. Consult with qualied licensed electrician for electrical installation.
Models ABSC02782
L1, L2, Ground to be eld wired
TO AVOID EQUIPMENT DAMAGE
DO NOT CONNECT POWER SUPPLY
DIR E CTLY TO HE ATING ELE ME NTS !!!
Note:
For illustrative purposes only. Consult with qualied licensed electrician for electrical installation.
Initial Start-Up and Checkout
1. Turn on control. Follow specic instruction sheet provided with controls.
2. Steam will begin to appear within 3-5 minutes at the steam head. S team will shut owhen desired tempera-
ture is reached and will automatically resume when room temperature drops below set point.
3. Steam will shut oautomatically when control timer reaches zero. To shut steam omanually, turn control
OFF. To clear steam from enclosure area, turn shower on before opening door.
4. If unit does not start and control does not turn ON (control display does not light up) then turn breaker o
for twenty seconds and try again.
Maintenance
steambath generators require little maintenance. Other than periodic draining, maintenance pro-
cedures are minimal. E very 2 months, or more often in hard” water areas, the manual drain valve should be
opened fully ushing out accumulated materials, salts and other particles which are natural by-products of boil-
ing water.
Note:
Flush a minimum o ve hours after the control has been turned oto insure that the water has cooled.
Draining immediately after a steam cycle may expose PVC and other piping to high
temperaturwater. Check local codes. The unit will rell automatically when the control is activated again.
In areas of hard water, a Aquasteam automatic drain valve system is recommended for generator longevity.
Contactor
L
N
Knock-out
(fitting omitted
for clarity)
Ground
Ground Lug
(behind probe)
!
warning
!
caution
!
caution
aquasteam
aquabrass.com