Owner`s manual

Residential Steambath Generator Systems
Operation of the In-Shower Control
On/Off Key
ON/OFF K ey is used to turn the steam generator
on/o.
Press On/Okey to turn steam generator on.
Press a second time to turn steam generator o.
A built-in timer automatically shuts the steam
generator oa predetermined period of time
after it has been started, unless the user does so
manually.
The "Display" indicates the S et Point temperature.
Pause Key
Pause key is used to turn the steam generator omomentarily.
Press Pause key to activate stand-by mode. Press a second time to resume normal function.
The "Set Point" indicator will ash on the function panel when Pause feature is activated.
Scroll Up & Scroll Down Keys
Up & Down arrow keys are used to set ambient temperature.
Pressing and holding keys will increase or decrease the current temperature setting.
The new and desired temperature setting ("S et Point" value) will remain for 5 seconds on the LE D display as
a conrmation of the new value you have selected.
The "Set Point" indicator shows the desired temperature, NOT the actual temperature.
Temperature can be adjusted in 1˚ F (0.5˚ C) increments from 105-120˚F (40.0- 49.0°C).
When ambient temperature is 1˚ F (0.5˚ C) lower than the Set Point, the heater automatically comes on
until the temperature reaches S et Point plus 1˚ F (0.5˚ C).
Care Tips for Controls
1 . U se only mild s oap and water on a soft cloth to c lean the control.
2. Do not use abrasive cleansers
Do not route the control or temperature sensor wiring inside conduit together with power
lines or c lose to hot water or steam piping. Doing so may result in an inoperative or hazardous installation.
Do not alter or modify the control. Doing so may result in an inoperative or hazardous installation.
!