1.
Measure the Length, Width, & Height (in ft.) of steam shower
or tub/shower being used. Multiply the Length x Width x Height
to get the B asic R oom Volume in CUB IC FE E T
L _______ x W _______ x H _______ = a
2.
Add to the room volume (a) for each of the following design features
that describe the steambath enclosure:
For natural stones: natural marble,stone
shale, glass block or concrete
Add 100%
Add 30%
Add 30%
Add 15% per foot
h
For ceramic or porcelain tile on cement board or mortar bed
For each exterior wall or extra glass panel
For each foot exceeding 8ft. in height
3.
Add all gures above to obtain the Total Room Volume required
Selection Chart
Maximum R oom
Model No. KW Vol. ft
3
(cu.meters)
Compare the Total Cubic Feet required (h) to the Specication Chart below and select the appropriate model.
Note:
To convert cubic feet ot cubic meters, divide cubic feet by 35.3.
Example: Total cubic feet required is 155. Divide by 35.3 to obtain 4.39 m3. Select model ABSC02787
IMPORTANT:
The guideline for
selecting the steambath generator is a
recommendation only. Because of vari-
ables in construction, these sizing
instructions and specications should be
considered as guidelines only.
Aquasteam will review the model
selected provided we receive complete
information, including working drawings,
specications, and pertinent electrical
and construction details. Otherwise the
manufacturer disclaims responsibility for
the sizing of a mod
el selected.
aquasteam
ABSC02787 7.5 151-225 (4.27-6.37)
ABSC02789 9 226-360 (6.39-10.19)
ABSC02782 12 476-575 (13.4-16.28)
aquabrass.com