Owner`s manual
Residential Steambath Generator Systems
4
Locating the Steam Generator Unit
Select a location as near as practical and outside the steam room. Typical locations include: closet, vanity
cabinet, heated attic or basement.
1. Locate steambath generator within 25 feet ( 7.6 m) of steam room.
2. Do not install steambath generator inside steam room.
3. Do not install steambath generator outdoors or wherever environmental conditions may affect the safety
and/or performance of the generator.
4. Do not install steambath generator or plumbing lines in unheated attic or any locations where water
could freeze.
5. Do not install steambath generator near ammable or corrosive materials or chemicals such as gasoline,
paint thinners, or the like. Installation in areas having high concentrations of chlorine (such as pool
equipment room) must be avoided.
6. I nstall steambath generator on a solid and level surface. Keyhole slots are provided on for wall mounting.
Insure the steam generator is properly secured and level when mounting with keyhole slots.
7. I nstall steambath generator in an upright position only.
8. I nstall anti-water hammer device as necessary.
9. Provide a minimum of 12 inches (30cm) at both ends and top of the steam generator or as required for
servicing. See page 6.
10. Provide unions as required to facilitate installation and disconnection of piping.
11.
IMPORTANT:
Steam line, safety valve, drain valve, plumbing and steamheads become hot during
operation and remain hot after shutdown for a period of time. Provide appropriate protection, including
insulating plumbing lines. Avoid plumbing runs and steamhead locations that can come in contact with
bathers, wiring and control cables.
12. controls can be located inside or outside of the steam room The temperature sensor must
always be placed in the steamroom.
Aquasteam steam generators are for residential use only
. Commercial or other non-residential
applications void the warranty and may adversely affect product performance. Use only aquasteam
series controls.
TypicaI aquasteam installation
!
warning
Control Cable
Field
installed
steam
supply pipe
Valve
is
shown open
Steam Generator
Field installed
power supply
Provideunions asrequired to facilitate
installtion and disconnect of piping
Field
installed
water
supplypipe
SteamHead
(shown with available acrylic shield)
In-Shower
Control
Temperature
s
Note:
For illustrative purposes only.
Consult with qualified designer, architect or
contractor for steam room construction details.
IMPORTANT: See pg. 5 & pg.11
for steam head and temperature
sensor location information.
aquasteam