Owner`s manual

Residential Steambath Generator Systems
7
!
caution
Electrical Specifications
All electrical wiring to be installed by a qualied licensed electrician in accordance with National
ElectrIcal Code and local electrical code.
Power Wiring
See Field Power Wiring Diagrams (Page 8)
1. Check power voltage. Use 240V/ 1ph to connect SH residential steambath generator.
2. Use minimum 90ºC /600V rated insulated copper conductors only for eld wiring, sized in accordance
with National E lectrical Code and local electrical code for the Amps in Ampere Chart.
3. Connect suitably sized equipment grounding wire to ground terminal provided.
4. Install a separate circuit breaker between supply and unit. Provide a power supply disconnect
within sight of the steam generator or one that is capable of being locked in the open position.
______________________________________________________________
Ampere Chart
______________________________________________________________
Maximum Room Voltage/ Wire Size
Model No. Volume ft
3
(m
2
) KW phase Amperes AWG (mm
2)
_______________________________________________________________________________________
ABSC02787 225(6.37) 7.5 240/1 32 8 (10 )
_______________________________________________________________________
ABSC02789 360 (10.19) 9.0 240/1 38 8 (10 )
__________________________________________________________________________
_________________________________________________________________________
Wiring Diagrams
Diagram
for ABSC02787
ABSC02789
Diagram
for ABSC02782
TO PROBE
HEATING
ELEMENT
CONTROL BOARD
GROUND
CONTACTOR
LIGHT
BLUE
WHITE
PURPLE
GREEN
C
S
WHITE
GRAY
BLACK
BLACK
L2
L1
WHITE
DARK
BLUE
TRANSFORMER
WATER
FEED
SOLENOID
VALVE
FUSES
PURPLE
POWERINPUT
Automatic Drain
(optional)
FACTOR
WIRING
FIELD
WIRING
LEGEND
(All Diagrams)
WATER
FEED
SOLENOID
VAVLE
HEATING
ELEMENT
CONTROL BOARD
GROUND
CONTACTOR
LIGHT
BLUE
WHITE
PURPLE
GREEN
C
S
WHITE
GRAY
POWER INPUT
BLACK
BLACK
L2
L1
WHITE
DARK
BLUE
TRANSFORMER
AUTOMATIC DRAIN
(optional)
TO PROBE
G
FACTORY
WIRING
FIELD
WIRING
LEGEND
(
All Diagrams)
aquasteam
TO AVOID EQUIPMENT DAMAGE DO NOT
CONNECT POWER SUPPLY DIRECTLY TO
HEATING ELEMENTS !!!
aquabrass.com
ABSC02782 575 (16.82) 12 240/1 50 6 (16)