Installation Instructions

Table Of Contents
1250$5&
,167580(17/$1',1*6<67(0
,167$//$7,21&200,66,21,1*+$1'%22.

1DYLD$YLDWLRQ$6

Figure 1-1 Station Control strap platform.
1.1.2 Remote Ports Access Level Configuration
The allowed access levels on REMOTE ports 1 and 2 on the RMS can be configured by set-
ting jumpers on the TCA1218A.
Set jumpers in S1 - S4 to configure which access levels that are allowed on remote ports 1
and 2.
Jumper in means that access level is allowed.
Jumper out means that access level is denied.
The table below shows which jumpers are connected to different ports and access levels.
Table 1-2 Access level strap settings.
1.1.3 Warning Configuration
Use the RMM Program to configure which warnings shall cause system warning i.e. illuminate
the RC main warning lamp.
1.2 Transmitter Alignments and Calibration
TEST EQUIPMENT REQUIRED:
Oscilloscope, general purpose
NM 3710 Field Test Set (with 20 dB attenuator)
BNC Test Cable
Frequency Counter RF
PORT ACC. LEVEL 2 ACC. LEVEL 3
Remote 1 Strap S1 Strap S2
Remote 2 Strap S3 Strap S4
1
2
3
4
5
6
7
8
9
10
HBK592-1