The remote line and remote controis connected to the CI 1376 connection interface board as
illustrated in Figure 5-6.
FSK_[A,B] is the modem line pair.
GND is main cabinet ground
A suitable female connector for the remote line is Weidemüller
BLZ-5.08/4
or equivalent.
Alternatively the remote control connection is done with a RS 232 interface, standard pin out 9
pins DSUB.
Figure 5-6 Remote control connection
CI 1376
PB 1378
REMOTE
CONTROL
LINE
TEMP
OUTDOOR
TEMP
INDOOR
AC LEVEL ANA CHA1
ANA CHA2 ANA CHA3
REMOTE RMM
RS232
REMOTE CONTOL
RS232
CONFIGURATION
1 - GND
2 - RC_LINE B
4 - Not used
1 - Not used
3 - RXD
2 - TXD
4 - Not used
5 - GND
6 - Not used
7 - Not used
8 - Not used
9 - Not used
REMOTE
CONTROL
REMOTE
CONTROL
LINE
RS-232
HBK788/3
2 - RC_LINE A