Operation Manual
Table Of Contents
- 1 SYSTEM DESCRIPTION
- 1.1 System Overview
- 1.2 Abbreviations
- 2 Technical specifications
- 2.1 Signal Minimum Performance GP
- 2.2 Environmental characteristics
- 2.3 EMC characteristics
- 2.4 Mechanical characteristics
- 2.5 Power supply
- 3 Main cabinet
- 3.1 Power on/off
- 3.2 Local Control Operation
- 3.3 Local Keyboard/Display Operation
- 3.3.1 The menu structure.
- 3.3.2 Handling the different menuscreens.
- 3.3.2.1 The menu screen
- 3.3.2.2 The readout screen
- 3.3.2.3 The toggle screens
- 3.3.2.4 Input/Store screen
- 3.3.2.5 The quick read screens
- 3.3.3 The access levels.
- 3.3.3.1 Level 2
- 3.3.3.2 Level 3
- 3.3.3.3 Leaving the access levels
- 3.3.4 Function listing
- 3.3.4.1 Level 1
- 3.3.4.2 Level 2
- 3.3.4.3 Level 3
- 3.3.5 The menu tree
- 4 Tower Equipment
- 4.1 Remote Control Operation
- 4.2 Remote Slave Operation
- 4.3 Interlock Switch Operation
- 5 Remote Maintenance and Monitoring Software
- 5.1 Introduction
- 5.2 User interface components
- 5.3 Shortcuts
- 5.4 Configuring the RMM system
- 5.5 Setting up ILS stations
- 5.6 Connecting to an ILS station
- 5.7 Monitor measurements and status
- 5.8 Monitor settings
- 5.9 TX settings
- 5.10 Power scaling
- 5.11 Front panel operation
- 5.12 Get historical data
- 5.13 Continuous data logging
- 5.14 Events
- 5.15 Test DDM
- 5.16 Set ILS date/time
- 5.17 User administration
- 5.18 ILS Modem settings
- 5.19 Upload configuration to ILS
- 5.20 Write configuration to file
- 5.21 Lamp mappings
- 5.22 Medium storage sample interval
- 5.23 Displaying stored measurements
- 5.24 DIAGNOSTICS
- 5.25 Exporting data
- 5.26 Printing reports
- 5.27 Print screen
- 5.28 Technical note - Leased line SETUP (USRobotics)
- 5.29 Technical note - Dial up connection SETUP (USRobotics)
- 5.30 Technical note - Leased line SETUP (WESTERMO)
- 5.31 Technical note - dial up SETUP (WESTERMO)
- 6 Periodic maintenance CAT I and II
- 6.1 Weekly inspections
- 6.2 Monthly inspections
- 6.3 Quarterly inspections
- 6.4 Annual inspections
- 6.4.1 RF Frequency check.
- 6.4.1.1 Course Transmitter Frequency
- 6.4.1.2 Clearance Transmitter Frequency
- 6.4.2 LF Frequency check.
- 6.4.3 Transmitter waveforms checks.
- 6.4.3.1 PHASE CORR. check.
- 6.4.3.2 SBO waveform checks.
- 6.4.3.3 RF Phase
- 6.4.3.4 CSB waveform check. LF phase
- 6.4.3.5 DDM and SDM check.
- 6.4.3.6 Not in use
- 6.4.4 (Not in use)CSB output power.
- 6.4.5 Monitor Alarm Limit checks.
- 6.4.5.1 CL DDM ALARM
- 6.4.5.2 CL SDM ALARM
- 6.4.5.3 CL RF ALARM
- 6.4.5.4 DS DDM ALARM
- 6.4.5.5 NF DDM ALARM
- 6.4.5.6 CLR DDM ALARM
- 6.4.5.7 CLR SDM ALARM
- 6.4.5.8 CLR RF ALARM
- 6.4.6 Near Field Monitor delay
- 6.4.7 20 seconds inhibit
- 6.4.8 Battery maintenance
- 6.4.9 Final check GP
- 7 Corrective maintenance
- 7.1 Overview
- 7.2 Diagnostic functions
- 7.3 LRU change procedures
- 7.4 Detailed description of the automatic diagnostic algorithms
- 7.4.1 Overview
- 7.4.2 Possible diagnostic solutions
- 7.4.3 Current data diagnostics
- 7.4.3.1 I2C read error on any board implies a failure on that board
- 7.4.3.2 Maintenance parameter warnings
- 7.4.3.2.1 External power supply tests
- 7.4.3.2.2 Power supply 1 and 2 tests
- 7.4.3.2.3 Maintenance warnings without follow-errors
- 7.4.3.2.4 Power amplifier tests
- 7.4.3.2.5 Monitor 1 and 2 frontend tests
- 7.4.3.2.6 Remote control tests
- 7.4.3.2.7 Transmitter control tests
- 7.4.3.2.8 Standby monitor tests
- 7.4.3.2.9 Standby monitor frontend tests
- 7.4.3.2.10 User defined parameters
- A Monitor and Maintenance Parameters
- A.1 Monitor Alarm Parameters
- A.2 Maintenance Parameters
- B Factory default configuration settings
- B.1 Cat I monitor LIMIT configuration
- B.1.1 Description of the FFM EXE AL limits
- B.1.2 Description of the CL IDENT and CLR IDENT limits
- B.2 Cat II monitor LIMIT configuration
- B.3 Cat III monitor LIMIT configuration
- B.4 Executive Monitor delay configuration
- B.5 Maintenance parameter configuration
- B.6 Oscillator 1 and 2 (OS 1221)
- B.6.1 LF generator 1 and 2 (LF 1223)
- B.6.2 TX 1 and 2, Course and Clearance
- B.6.3 RF frontends for monitor 1, 2 and standby monitor (MF 1211/1219)
- B.6.4 Monitor 1, 2 and standby (MO 1212)
- B.6.5 Transmitter control board (TCA 1216)
- B.6.6 Remote monitoring board (RMA 1215)
- B.6.7 Power supply 1 and 2 (PS 1227)
- B.6.8 External power
- B.6.9 User defined inputs
- B.7 Maintenance delay configuration
- B.8 Morse code configuration
- B.9 Typical TX Adjustments values
- B.10 User administration configuration
- B.11 Frequency configuration strap settings
- B.11.1 OS1221B strap settings for 2-frequency GP
- C Maintenance Procedures
23(5$7,1*0$18$/
1250$5&
,167580(17/$1',1*6<67(0
&RUUHFWLYHPDLQWHQDQFH 1DYLD$YLDWLRQ$6
measured with the 3710.
DDM Check that the CL DDM readings are the same as with 3710.
ADJUSTMENT (NF CHANNEL):
Pre-check Check that all monitor inputs from MCU are correct. (Use field measurement
instrument NM3710). Make a note of the values.
RF-level Set R3338 in middle position. Set strap fields S++ on connector P3002 and
adjust R3338 until TP3023 reads 240mV. Adjust RF potentiometer R3342 on
front of MF1219 card until NF RF level reads exactly 3,0 volts.
AGC Time Adjust AGC timing pot R3049 until the DC value measured at TP4 are the
same with transmitters on and off.
SDM Adjust SDM pot R3048 until the NF SDM readings is the same as the value
measured with the 3710.
DDM Check that the NF DDM reading is the same as with 3710.
CHECK:
Power down system. Remove the extension card and place the MF1219 inside cabinet. Turn
transmitters on.
Monitor Use RMM software to check monitor readings for all four channels. RF level
should now be 3.0V, SDM 40% and DDM 0,0%. It might be necessary to make
small adjustments to the RF Level with potentiometers R342 (DS), R1342
(CLR), R2342 (CL) and R3342 (NF).
Maintenance Use RMM software to check maintenance values for MF1219 card. There shall
be no warnings (if the transmitters are on).
7.3.3 PS1227 replacement
PREPARATIONS:
Power down system. Remove old unit and place the new unit in the vacant slot.
ADJUSTMENT:
No adjustments are necessary.
CHECK:
System: Remove the other PS1227 unit. Turn transmitters on and set the correct trans-
mitter to air (Transmitter 1 to check Powersupply 1). Check the monitor read-
ings to verify correct transmitter behaviour.
Maintenance Power down the ILS, re-insert the other PS1227 unit, and power up again.
Check the RMM maintenance readings of the PS1227 system voltages; check
both powersupplies.
7.3.4 OS1221 replacement
PREPARATIONS:
Power down system. Remove old unit. Write down the strap settings of the old OS1221A
(LLZ) or 1221B (GP) card and make sure the new card is identically configured. Please refer
to Appendix B to verify the frequency selection.
ADJUSTMENT:
The frequency of the RF output signal is normally factory adjusted. To adjust the frequency,
power down the ILS, remove the shield, place the OS1221 card on an extender board and
adjust by fine-tuning the capacitor C1. Turn off 90, 150 and 1020 Hz modulation tones from