Operation Manual
Table Of Contents
- 1 SYSTEM DESCRIPTION
- 1.1 System Overview
- 1.2 Abbreviations
- 2 Technical specifications
- 2.1 Signal Minimum Performance GP
- 2.2 Environmental characteristics
- 2.3 EMC characteristics
- 2.4 Mechanical characteristics
- 2.5 Power supply
- 3 Main cabinet
- 3.1 Power on/off
- 3.2 Local Control Operation
- 3.3 Local Keyboard/Display Operation
- 3.3.1 The menu structure.
- 3.3.2 Handling the different menuscreens.
- 3.3.2.1 The menu screen
- 3.3.2.2 The readout screen
- 3.3.2.3 The toggle screens
- 3.3.2.4 Input/Store screen
- 3.3.2.5 The quick read screens
- 3.3.3 The access levels.
- 3.3.3.1 Level 2
- 3.3.3.2 Level 3
- 3.3.3.3 Leaving the access levels
- 3.3.4 Function listing
- 3.3.4.1 Level 1
- 3.3.4.2 Level 2
- 3.3.4.3 Level 3
- 3.3.5 The menu tree
- 4 Tower Equipment
- 4.1 Remote Control Operation
- 4.2 Remote Slave Operation
- 4.3 Interlock Switch Operation
- 5 Remote Maintenance and Monitoring Software
- 5.1 Introduction
- 5.2 User interface components
- 5.3 Shortcuts
- 5.4 Configuring the RMM system
- 5.5 Setting up ILS stations
- 5.6 Connecting to an ILS station
- 5.7 Monitor measurements and status
- 5.8 Monitor settings
- 5.9 TX settings
- 5.10 Power scaling
- 5.11 Front panel operation
- 5.12 Get historical data
- 5.13 Continuous data logging
- 5.14 Events
- 5.15 Test DDM
- 5.16 Set ILS date/time
- 5.17 User administration
- 5.18 ILS Modem settings
- 5.19 Upload configuration to ILS
- 5.20 Write configuration to file
- 5.21 Lamp mappings
- 5.22 Medium storage sample interval
- 5.23 Displaying stored measurements
- 5.24 DIAGNOSTICS
- 5.25 Exporting data
- 5.26 Printing reports
- 5.27 Print screen
- 5.28 Technical note - Leased line SETUP (USRobotics)
- 5.29 Technical note - Dial up connection SETUP (USRobotics)
- 5.30 Technical note - Leased line SETUP (WESTERMO)
- 5.31 Technical note - dial up SETUP (WESTERMO)
- 6 Periodic maintenance CAT I and II
- 6.1 Weekly inspections
- 6.2 Monthly inspections
- 6.3 Quarterly inspections
- 6.4 Annual inspections
- 6.4.1 RF Frequency check.
- 6.4.1.1 Course Transmitter Frequency
- 6.4.1.2 Clearance Transmitter Frequency
- 6.4.2 LF Frequency check.
- 6.4.3 Transmitter waveforms checks.
- 6.4.3.1 PHASE CORR. check.
- 6.4.3.2 SBO waveform checks.
- 6.4.3.3 RF Phase
- 6.4.3.4 CSB waveform check. LF phase
- 6.4.3.5 DDM and SDM check.
- 6.4.3.6 Not in use
- 6.4.4 (Not in use)CSB output power.
- 6.4.5 Monitor Alarm Limit checks.
- 6.4.5.1 CL DDM ALARM
- 6.4.5.2 CL SDM ALARM
- 6.4.5.3 CL RF ALARM
- 6.4.5.4 DS DDM ALARM
- 6.4.5.5 NF DDM ALARM
- 6.4.5.6 CLR DDM ALARM
- 6.4.5.7 CLR SDM ALARM
- 6.4.5.8 CLR RF ALARM
- 6.4.6 Near Field Monitor delay
- 6.4.7 20 seconds inhibit
- 6.4.8 Battery maintenance
- 6.4.9 Final check GP
- 7 Corrective maintenance
- 7.1 Overview
- 7.2 Diagnostic functions
- 7.3 LRU change procedures
- 7.4 Detailed description of the automatic diagnostic algorithms
- 7.4.1 Overview
- 7.4.2 Possible diagnostic solutions
- 7.4.3 Current data diagnostics
- 7.4.3.1 I2C read error on any board implies a failure on that board
- 7.4.3.2 Maintenance parameter warnings
- 7.4.3.2.1 External power supply tests
- 7.4.3.2.2 Power supply 1 and 2 tests
- 7.4.3.2.3 Maintenance warnings without follow-errors
- 7.4.3.2.4 Power amplifier tests
- 7.4.3.2.5 Monitor 1 and 2 frontend tests
- 7.4.3.2.6 Remote control tests
- 7.4.3.2.7 Transmitter control tests
- 7.4.3.2.8 Standby monitor tests
- 7.4.3.2.9 Standby monitor frontend tests
- 7.4.3.2.10 User defined parameters
- A Monitor and Maintenance Parameters
- A.1 Monitor Alarm Parameters
- A.2 Maintenance Parameters
- B Factory default configuration settings
- B.1 Cat I monitor LIMIT configuration
- B.1.1 Description of the FFM EXE AL limits
- B.1.2 Description of the CL IDENT and CLR IDENT limits
- B.2 Cat II monitor LIMIT configuration
- B.3 Cat III monitor LIMIT configuration
- B.4 Executive Monitor delay configuration
- B.5 Maintenance parameter configuration
- B.6 Oscillator 1 and 2 (OS 1221)
- B.6.1 LF generator 1 and 2 (LF 1223)
- B.6.2 TX 1 and 2, Course and Clearance
- B.6.3 RF frontends for monitor 1, 2 and standby monitor (MF 1211/1219)
- B.6.4 Monitor 1, 2 and standby (MO 1212)
- B.6.5 Transmitter control board (TCA 1216)
- B.6.6 Remote monitoring board (RMA 1215)
- B.6.7 Power supply 1 and 2 (PS 1227)
- B.6.8 External power
- B.6.9 User defined inputs
- B.7 Maintenance delay configuration
- B.8 Morse code configuration
- B.9 Typical TX Adjustments values
- B.10 User administration configuration
- B.11 Frequency configuration strap settings
- B.11.1 OS1221B strap settings for 2-frequency GP
- C Maintenance Procedures
1DYLD$YLDWLRQ$6 & RUUHFWLYHPDLQWHQDQFH
23(5$7,1*0$18$/1250$5&
,167580(17/$1',1*6<67(0
RMM software. Measure the RF frequency at the CSB outlet at the front of the ILS cabinet
CHECK:
Power down the system and place the card inside cabinet.
Maintenance Check the maintenance parameters for the OS1221 unit.
7.3.5 MO1212 replacement
PREPARATIONS:
• Power down system. Remove old unit.
• Compare the version numbers of the removable EPROM on the card. Make sure the new
unit contains the same or newer EPROM software version.
• Place the new card in the vacant slot.
ADJUSTMENT:
1. Use RMM software to upload configuration to the replaced monitor board.
2. Check that the CL, DS, NF and CLR measurements in the RMM software are the same as
before the replacement. Adjust the channel gains on the corresponding monitor frontend
board if any discrepancies are seen.
CHECK:
Verify monitor limits with an external ILS generator, as described in chapter 6.
Monitor Make sure the ILS is operating in normal state (transmitters on) and check that
all parameters are normal.
Maintenance Check the maintenance parameters for the MO1212 unit.
Final Make a printout of the monitor values (Print Report) and settings. Compare with
previous report taken before the board was replaced. Check that the alarm lim-
its and delays are the same as before.
7.3.6 TCA1218 replacement
PREPARATIONS:
Power down system. Remove old unit.
ADJUSTMENT:
Make sure that all configuration straps (U1) are set as on the previous module. The best way
to do this is to exchange the U1 component platform.
Compare the version numbers of the EPROM- and FPGA units on the board. Make sure the
new unit contains the same EPROM and FPGA versions.
CHECK:
Start up: Check that the ILS front panel display shows the correct equipment setting
(e.g. NM7013 Two-frequency Localizer).
Maintenance: Check the maintenance parameters for the TCA1218 unit.
Front Panel: Set the local/remote switch in local position and the auto/manual switch in man-
ual position. Check that it is possible to turn transmitters on/off and perform a
changeover.
Integrity test: Turn main transmitter(s) on. Set the auto/manual switch in auto position. Use
RMM software to switch off the 90 Hz tones of both main transmitters. Observe
that a changeover, and after a while a shutdown takes place.